Summary

Product Identification

  • Model: SU-820FA
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound
  • Active Membrane Surface Area: 31.4 m² (338 ft²) (nominal)
  • Nominal Membrane Surface Area: 32 m² (345 ft²)

Product Water

  • Salt Rejection: 99.75 % (99.6% minimum)
  • Product Flow Rate: 19 m³/day (5’020 gpd) (16.5 m³/d (4360 gpd) minimum)

Performance Test Conditions:

  • Pressure: 5.5 MPa (800 psi)
  • Temperature: 25 °C (77 °F)
  • Feed Concentration: 3.5 % as Sea Water
  • Brine Flow Rate: 80 l/min (21.1 gpm)
  • Feed pH: 6.5

Operating Limits

  • Recommended Operating Pressure: < 6860 kPa (70 kg/cm² / 1000 psi)
    • Maximum Operating Pressure: 6860 kPa (70 kg/cm²) (1000 psi)
  • Recommended Feedwater Temperature: < 35 °C (95 °F)
    • Maximum Feedwater Temperature: 45 °C (113 °F)
  • Feedwater Silt Density Index (SDI₁₅): < 4
  • Feedwater Chlorine Concentration: 0 ppm
  • pH Range, Continuous Operation: 3 - 9 (Both feed and brine water must meet this range.)
  • pH Range, Chemical Cleaning: 2 - 10
  • Feed Flow Rate per Vessel: < 200 l/min (52.8 gpm)
  • Brine Flow Rate per Vessel: > 40 l/min (10.8 gpm)
  • Brine/Permeate Flow Ratio (per element): > 6
  • Pressure Drop (per Element): < 98 kPa (1 kg/cm²) (14 psi)
  • Pressure Drop (per Vessel): < 196 kPa (2 kg/cm²) (29 psi)

Mechanical / Hydraulic

The physical dimensions of the element are provided in millimeters within a diagram that is not readable as text. See the official PDF for exact tabulated values and diagrams.