Back to Toray Membranes
Toray logo

Datasheet summary

SUL-G20F

Engineering summary from PDF text extraction for SUL-G20F. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: SUL-G20F
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound

Performance Specification

Test conditions for performance data:

  • Feed Water Pressure: 0.75 MPa (110 psi)
  • Feed Water Temperature: 25 °C (77 °F)
  • Feed Water Concentration: 500 mg/L as NaCl
  • Brine Flow Rate: 80 L/min. (21 gpm)
  • Feed Water pH: 6.5
  • Salt Rejection: 99.5 % (99.0 % minimum*)
  • Product Flow Rate: 37 m³/day (9800 gpd) (32 m³/day (8450 gpd) minimum*)
  • Membrane Surface Area (Nominal): 39 m² (420 ft²)
    • Note: The membranes area stated is a nominal value and not a guaranteed specification.

*For any single element

Mechanical / Hydraulic

Dimensions:

  • Overall Length: 1016 mm
  • Outer Diameter: 101 mm (φ101)
  • Permeate Tube Diameter: 21 mm (φ21)
  • Other stated dimensions: 15 mm, 15 mm, 22 mm
    • All dimensions shown in millimeters.

Operating limits

Recommended design conditions:

  • Feed Water Pressure: <1.0 MPa (150 psi)
  • Feed Water Temperature: <35 °C (95 °F)
  • Feed Water Turbidity (SDI): <4 (measured according to ASTM D4189)
  • Feed Water pH Range (Continuous Operation): 3–9
  • Feed Water pH Range (Chemical Cleaning): 2–11
  • Feed Flow Rate per Vessel: <200 L/min. (52 gpm)
  • Brine Flow Rate per Vessel: >40 L/min. (11 gpm)
  • Brine/Permeate Flow Ratio: >6 (ratio at last element)
  • Pressure Drop (per Element): <0.10 MPa (14 psi)
  • Pressure Drop (per Vessel): <0.20 MPa (29 psi)

Maximum limits:

  • Maximum Feed Water Pressure: 4.1 MPa (600 psi)
  • Maximum Feed Water Temperature: 40 °C (104 °F)

General operating notes:

  • If operated outside the recommended design range, the effective membrane life may be reduced.
  • High flux operation on feed water turbidity greater than 3 or 4 SDI generally results in frequent cleaning requirements.
  • Element(s) must be cleaned when pressure drop increases up to 1.5 times of initial value.
  • Sterilization must follow guidances in Toray's technical bulletin.

Disclaimer: This summary is based on text extracted from a PDF datasheet. This extraction may miss figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.