Back to Toray Membranes
Toray logo

Datasheet summary

SUL-G20FTS

Engineering summary from PDF text extraction for SUL-G20FTS. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: SUL-G20FTS
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound

Performance Specification

  • Salt Rejection: 99.5 % (99.0 % minimum for any single element)
  • Product Flow Rate: 36 m³/day (9500 gpd) (29 m³/day (7660 gpd) minimum for any single element)

Test Conditions:

  • Feed Water Pressure: 0.75 MPa (110 psi)
  • Feed Water Temperature: 25 °C (77 °F)
  • Feed Water Concentration: 500 mg/L as NaCl
  • Brine Flow Rate: 80 L/min. (21 gpm)
  • Feed Water pH: 6.5

Operating Limits

The following are recommended design conditions. Operation outside this range may reduce effective membrane life.

  • Recommended Feed Water Pressure: 1.0 MPa (150 psi)
  • Maximum Feed Water Pressure: 4.1 MPa (600 psi)
  • Recommended Feed Water Temperature: 35 °C (95 °F)
  • Maximum Sanitization Temperature: 85 °C (185 °F)
  • Feed Water Turbidity (SDI): 4
  • Feed Water pH Range, Continuous Operation: 3 – 9
  • Feed Water pH Range, Chemical Cleaning: 2 – 11
  • Feed Flow Rate per Vessel: 200 L/min. (52.8 gpm)
  • Brine Flow Rate per Vessel: 40 L/min. (10.6 gpm)
  • Brine/Permeate Flow Ratio: 6 (at last element)

Mechanical / Hydraulic

  • Dimensions: All dimensions shown in millimeters. See the official PDF for exact tabulated values and diagrams.
  • Pressure Drop (per Element): 0.10 MPa (14 psi)
  • Pressure Drop (per Vessel): 0.20 MPa (29 psi)
  • Elements must be cleaned when pressure drop increases up to 1.5 times of initial value.

Disclaimer: This summary is based on extracted text and may miss figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.