Summary

Product Identification

  • Model: SUL-G20P
  • Description: Low elution, easy to rinse and energy saving
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound

Performance Specification

  • Product Flow Rate: 32 m³/day (8500 gpd)
  • Minimum Product Flow Rate: 28 m³/day (7400 gpd) (for any single element)

Test Conditions

  • Feed Water Pressure: 0.75 MPa (110 psi)
  • Feed Water Temperature: 25 °C (77 °F)
  • Feed Water Concentration: Pure water
  • Brine Flow Rate: 80 L/min. (2 gpm)

Operating Limits

  • Maximum Feed Water Pressure: 4.1 MPa (600 psi)
  • Maximum Feed Water Temperature: 45 °C (113 °F)
  • Recommended Feed Water Pressure: < 1.5 MPa (214 psi)
  • Recommended Feed Water Temperature: < 35 °C (95 °F)
  • Feed Water pH Range, Chemical Cleaning: 2 – 11
  • Recommended Feed Flow Rate per Vessel: < 200 L/min. (52 gpm)
  • Recommended Brine Flow Rate per Vessel: > 40 L/min. (11 gpm)
  • Recommended Pressure Drop (per Element): < 0.10 MPa (14 psi)
  • Recommended Pressure Drop (per Vessel): < 0.20 MPa (29 psi)