Datasheet summary
TM820-400
Engineering summary from PDF text extraction for TM820-400. Verify every value with the OEM datasheet.
Summary
Product identification
- Product: TM820-400
- Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
- Membrane Surface Area: 400 ft² (37 m²)
- Brine spacer thickness: 28 mil
Performance Specification
Performance is based on the following test conditions:
- Feed Water Pressure: 800 psi (5.5 MPa)
- Feed Water Temperature: 77 °F (25 °C)
- Feed Water Concentration: 32,000 mg/L as NaCl
- Recovery Rate: 8 %
- Feed Water pH: 7
Under these conditions, the element yields:
- Salt Rejection: 99.75 %
- Product Flow Rate: 6,500 gpd (25 m³/day)
Minimum specified performance:
- Minimum Salt Rejection: 99.5 %
- Minimum Product Flow Rate: 5,200 gpd (20 m³/day)
Note: The membrane area stated is a nominal value and is not a guaranteed specification.
Operating limits
- Maximum Operating Pressure: 1000 psi (6.9 MPa)
- Maximum Feed Water Temperature: 113 °F (45 °C)
- Maximum Feed Water Silt Density Index: 5
- Feed Water Chlorine Concentration: Not Detectable
- Feed Water pH Range, Continuous Operation: 2 - 11
- Feed Water pH Range, Chemical Cleaning: 1 - 12
- Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
- Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)
Mechanical / hydraulic
All dimensions are shown in inches (millimeters).
- Overall Length: 40 (1016)
- Outer Diameter: 7.9 (201)
- Permeate Tube Diameter: 1.125 (29)
Operating Information
- All elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and then vacuum bagged in oxygen barrier bags.
- For biological growth prevention during short term storage, shipment, or system shutdown, it is recommended that elements be immersed in a protective solution containing 500 - 1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.
- Permeate from the first hour of operation should be discarded.
- The customer is fully responsible for the effects of chemicals that are incompatible with the elements. Their use will void the element Limited Warranty.
- For recommended design range, consult the latest Toray technical bulletin, design guidelines, computer design program, and/or an application specialist. Not strictly following operating limits voids the Limited Warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.