Summary

Product Identification

  • Product Line: Sea Water RO Elements
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite

Performance Specifications

TM820F-370

  • Product Flow Rate: 6,700 gpd (25.3 m³/d)
  • Salt Rejection: 99.70%
  • Membrane Area: 370 ft² (34 m²)
  • Diameter: 8 inch
  • Feed Spacer Thickness: 28 mil

TM820F-400

  • Product Flow Rate: 7,200 gpd (27.3 m³/d)
  • Salt Rejection: 99.70%
  • Membrane Area: 400 ft² (37 m²)
  • Diameter: 8 inch
  • Feed Spacer Thickness: 31 mil

Test Conditions

  • Feed Water Pressure: 800 psi (5.52 MPa)
  • Feed Water Temperature: 77°F (25°C)
  • Feed Water Concentration: 32,000 mg/l NaCl
  • Recovery Rate: 8%
  • Feed Water pH: 8
  • Minimum Salt Rejection: 99.5%
  • Minimum Product Flow Rate:
    • TM820F-370: 6,700 gpd (25.3 m³/d)
    • TM820F-400: 7,200 gpd (27.3 m³/d)

Operating Limits

  • Maximum Operating Pressure: 1000 psi (6.9 MPa)
  • Maximum Feed Water Temperature: 113°F (45°C)
  • Maximum Feed Water SDI₁₅: 5
  • Feed Water Chlorine Concentration: Not detectable
  • Feed Water pH Range, Continuous Operation: 2-11
  • Feed Water pH Range, Chemical Cleaning: 1-12
  • Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
  • Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)

Mechanical / Hydraulic

  • Dimensions are shown in Inches (millimeter). The nominal length is 40 inches (1,016 mm) and the nominal diameter is 7.9 inches (201 mm) for the active membrane area. See the official PDF for exact tabulated values or diagrams detailing specific dimensions, including end-caps and permeate tube.

Operating Information

  • For recommended design ranges, consult the latest Toray technical bulletin, design guidelines, computer design program, or an application specialist.
  • Failure to strictly follow operating limits given in this Product Information Bulletin will void the Limited Warranty.
  • All elements are wet tested, treated with tested feed water solution, and vacuum packed in oxygen barrier bags with deoxidant.
  • To prevent biological growth during system shutdown, it is recommended to flush Toray elements with seawater for 30-60 minutes once every two days.
  • The presence of free chlorine and other oxidizing agents (especially in combination with heavy metals acting as oxidation catalysts) in the feed water can cause unexpected oxidation of the membrane. It is strongly recommended to remove these oxidizing agents before operating the RO system.
  • Permeate from the first hour of operation shall be discarded.
  • Customers are fully responsible for the effects of chemicals incompatible with the elements; their use will void the element Limited Warranty.

Notice

  • Toray accepts no responsibility for results obtained by the application of this information or the safety or suitability of Toray's products, either alone or in combination with other products. Users are advised to make their own tests to determine the safety and suitability of each product combination for their own purposes.