Back to Toray Membranes
Toray logo

Datasheet summary

TM820V-400

Engineering summary from PDF text extraction for TM820V-400. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Type: Sea Water RO Elements
  • Models: TM820V-400, TM820V-440
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite

Performance Specifications

Nominal Performance

(Measured at Test Conditions, typical values)

TypeProduct Flow Rate gpd (m³/d)Feed Spacer Thickness milSalt Rejection %Membrane Area ft² (m²)Diameter Inch
TM820V-4009,900 (37.5)2899.8440 (41)8”
TM820V-4409,000 (34.1)2899.8400 (37)8”

Minimum Product Flow Rate

  • TM820V-400: 7,500 gpd (28.4 m³/d)
  • TM820V-440: 8,250 gpd (31.2 m³/d)

Test Conditions

  • Feed Water Pressure: 800 psi (5.52 MPa)
  • Feed Water Temperature: 77°F (25℃)
  • Feed Water Concentration: 32,000 mg/l NaCl
  • Recovery Rate: 8%
  • Feed Water pH: 8
  • Boron addition for test: 5 mg/l Boron added to Feed water (at pH 8)

Rejection Rates

  • Minimum Salt Rejection: 99.5%
  • Boron Rejection (typical value): 92% at pH 8 (with 5 mg/l Boron added to Feed water)

Operating Limits

  • Maximum Operating Pressure: 1200 psi (8.3 MPa)
  • Maximum Feed Water Temperature: 113 ˚F (45 ˚C)
  • Maximum Feed Water SDI₁₅: 5
  • Feed Water Chlorine Concentration: Not Detectable
  • Feed Water pH Range, Continuous Operation: 2-11
  • Feed Water pH Range, Chemical Cleaning: 1-12
  • Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
  • Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)

Mechanical / Hydraulic

  • Overall Element Length: 40 inches (1,016 mm)
  • Element Diameter: 7.9 inches (201 mm)
  • Permeate Tube Diameter: 1.125 inches (29 mm)
  • Flow direction: Feed Water (F), Concentrated Brine (B), Permeate (indicated by diagram)

Operating Information

  • For recommended design range, consult the latest technical bulletin, design guidelines, computer design program, or an application specialist.
  • Operating limits must be strictly followed to maintain the Limited Warranty.
  • Elements are wet tested, treated with tested feed water solution, and vacuum packed in oxygen barrier bags with deoxidant.
  • To prevent biological growth during system shutdown, perform 30-60 minutes flushing with seawater once every two days.
  • Permeate from the first hour of operation shall be discarded.
  • Users are responsible for effects of incompatible chemicals; their use will void the Limited Warranty.

Disclaimer

This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet