Datasheet summary

TM840R-1760

Engineering summary from PDF text extraction for TM840R-1760. Verify every value with the OEM datasheet.

Summary

Product identification

  • Type: Seawater Reverse Osmosis (RO) Element
  • Model: TM840R-1760
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Diameter: 16 inches
  • Membrane Area: 1,760 ft² (164 m²)
  • Feed Spacer Thickness: 28 mil

Performance

The following performance data is based on specific test conditions:

  • Feed Water Pressure: 800 psi (5.52 MPa)
  • Feed Water Temperature: 77°F (25 ℃)
  • Feed Water Concentration: 32,000 mg/l NaCl
  • Recovery Rate: 8%
  • Feed Water pH: 8

Performance values for TM840R-1760

  • Minimum Salt Rejection: 99.5%
  • Nominal Salt Rejection: 99.8%
  • Minimum Product Flow Rate: 30,100 gpd (114 m³/d)
  • Nominal Product Flow Rate: 39,600 gpd (150 m³/d)
  • Boron Rejection (typical value): 99.5%
  • Boron Rejection (at pH 8 with 5 mg/l Boron in feed water): 95%

Operating limits

  • Maximum Operating Pressure: 1200 psi (8.3 MPa)
  • Maximum Feed Water Temperature: 113°F (45℃)
  • Maximum Feed Water SDI₁₅: 5
  • Feed Water Chlorine Concentration: Not detectable
  • Feed Water pH Range (Continuous Operation): 2-11
  • Feed Water pH Range (Chemical Cleaning): 1-13

Mechanical / Hydraulic

  • Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
  • Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)

Operating information

  • For detailed design ranges, consult Toray's technical bulletin, design guidelines, computer design program, or an application specialist. Failure to follow operating limits may void the Limited Warranty.
  • All elements are wet tested, treated with tested feed water solution, and vacuum packed in oxygen barrier bags with deoxidant.
  • To prevent biological growth during system shutdown, flushing with seawater for 30-60 minutes every two days is recommended.
  • The presence of free chlorine and other oxidizing agents, especially with heavy metals acting as oxidation catalysts, can cause unexpected membrane oxidation. It is strongly recommended to remove these oxidizing agents from feed water before RO system operation.
  • Permeate from the first hour of operation shall be discarded.
  • Customers are fully responsible for the effects of chemicals incompatible with the elements; their use will void the Limited Warranty.

Notice

  • All data may change without prior notice due to technical modifications or production changes.

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.