TM840V-1760

Engineering summary from PDF text extraction for TM840V-1760. Verify every value with the OEM datasheet.

Summary

Product Identification

This document describes Seawater RO Elements, specifically the TM840V-1760 model.

Membrane Type

  • Cross Linked Fully Aromatic Polyamide Composite

Test Conditions

Performance data is typically measured under the following conditions:

  • Feed Water Pressure: 800 psi (5.52 MPa)
  • Feed Water Temperature: 77°F (25 ℃)
  • Feed Water Concentration: 32,000 mg/l NaCl
  • Recovery Rate: 8%
  • Feed Water pH: 8
  • Boron added to Feed water: 5 mg/l (for Boron Rejection test)

Performance Specifications

TM840V-1760

  • Product Flow Rate (Nominal): 39,600 gpd (150 m³/d)
  • Minimum Product Flow Rate: 31,700 gpd (120 m³/d)
  • Salt Rejection: 99.8% (nominal)
  • Minimum Salt Rejection: 99.5%
  • Boron Rejection (typical value): 92% at pH8

Other Models (for comparison)

  • TM840M-1760:
    • Product Flow Rate (Nominal): 30,800 gpd (117 m³/d)
    • Minimum Product Flow Rate: 24,600 gpd (93 m³/d)
    • Salt Rejection: 99.8%
    • Boron Rejection (typical value): 95% at pH8
  • TM840R-1760:
    • Product Flow Rate (Nominal): 37,600 gpd (142 m³/d)
    • Minimum Product Flow Rate: 30,100 gpd (114 m³/d)
    • Salt Rejection: 99.8%
    • Boron Rejection (typical value): 95% at pH8

Operating Limits

  • Maximum Operating Pressure: 1200 psi (8.3 MPa)
  • Maximum Feed Water Temperature: 113°F (45℃)
  • Maximum Feed Water SDI₁₅: 5
  • Feed Water Chlorine Concentration: Not detectable
  • Feed Water pH Range, Continuous Operation: 2-11
  • Feed Water pH Range, Chemical Cleaning: 1-13
  • Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
  • Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)

Mechanical / Hydraulic Data

  • Membrane Area: 1,760 ft² (164 m²)
  • Feed Spacer Thickness: 28 mil
  • Diameter: 16"
  • Dimensions are shown in Inches (millimeter). (Specific overall dimensions are not clearly extracted from the provided text but diagrams are indicated in the original PDF).

Operating Information

  • For recommended design range, it is advised to consult the latest technical bulletin, design guidelines, computer design program, or an application specialist.
  • The Limited Warranty will be null and void if operating limits are not strictly followed.
  • Elements are wet tested, treated with tested feed water solution, and vacuum packed in oxygen barrier bags with deoxidant.
  • To prevent biological growth during system shutdown, flushing of elements with seawater for 30-60 minutes every two days is recommended.
  • The presence of free chlorine and other oxidizing agents, especially with heavy metals acting as oxidation catalysts in feed water, can cause unexpected membrane oxidation. It is strongly recommended to remove these oxidizing agents from feed water before operating the RO system.
  • Permeate from the first hour of operation shall be discarded.
  • The customer is fully responsible for the effects of chemicals that are incompatible with the elements, and their use will void the Limited Warranty.

Disclaimer

This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.