Datasheet summary
TMG20-370-400-440
Engineering summary from PDF text extraction for TMG20-370-400-440. Verify every value with the OEM datasheet.
Summary
Product identification
These are Toray Ultra Low Pressure Brackish Water RO Elements, featuring a Cross Linked Fully Aromatic Polyamide Composite membrane.
Performance Test Conditions
- Feed Water Pressure: 110 psi (0.76 MPa)
- Feed Water Temperature: 77 °F (25 °C)
- Feed Water Concentration: 500 mg/l NaCl
- Recovery Rate: 15 %
- Feed Water pH: 7
Product Water
- Minimum Salt Rejection: 99.0 %
- Minimum Product Flow Rate:
- TMG10: 2,000 gpd (7.6 m³/d)
- TMG20-370: 7,500 gpd (28.4 m³/d)
- TMG20-400: 8,200 gpd (31.0 m³/d)
- TMG20-430: 8,800 gpd (33.3 m³/d)
Operating Limits
- Maximum Operating Pressure: 365 psi (2.5 MPa)
- Maximum Feed Water Temperature: 113 °F (45 °C)
- Maximum Feed Water SDI₁₅: 5
- Feed Water Chlorine Concentration: Not Detectable
- Feed Water pH Range, Continuous Operation: 2-11
- Feed Water pH Range, Chemical Cleaning: 1-12
- Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
- Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)
Mechanical / Hydraulic
All dimensions are shown in inches (millimeters).
- Overall Element Length: 40 inches (1016 mm)
- Overall Element Diameter (4" type): 4 inches (101 mm)
- Overall Element Diameter (8" type): 7.9 inches (201 mm)
| Type | Diameter | Membrane Area ft² (m²) | Salt Rejection % | Product Flow Rate gpd (m³/d) |
|---|---|---|---|---|
| TMG10 | 4" | 87 (8) | 99.5 | 2,400 (9.1) |
| TMG20-370C | 8" | 370 (34) | 99.5 | 9,500 (36.0) |
| TMG20-400C | 8" | 400 (37) | 99.5 | 10,200 (38.6) |
| TMG20-430C | 8" | 430 (40) | 99.5 | 11,000 (41.6) |
Operating Information
Elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and then vacuum packed in oxygen barrier bags. To prevent biological growth during short-term storage, shipment, or system shutdown, it is recommended that Toray elements be immersed in a protective solution containing 500 - 1,000 ppm of sodium bisulfite (food grade) dissolved in permeate. Permeate from the first hour of operation shall be discarded.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.