Datasheet summary
TMH10A
Engineering summary from PDF text extraction for TMH10A. Verify every value with the OEM datasheet.
Summary
Product Identification
These are Brackish Water RO Elements. Models include:
- TMH10A
- TMH20A-370
- TMH20A-400
- TMH20A-430
- TMH20A-440
Membrane Type
- Cross Linked Fully Aromatic Polyamide Composite
Test Conditions
Performance specifications are based on the following test conditions:
- Feed Water Pressure: 100 psi (0.69 MPa)
- Feed Water Temperature: 77°F (25℃)
- Feed Water Concentration: 500 mg/l NaCl
- Recovery Rate: 15%
- Feed Water pH: 7
Product Water
- Minimum Salt Rejection: 99.0%
Minimum Product Flow Rate:
- TMH10A: 1,900 gpd (7.2 m³/d)
- TMH20A-370: 8,200 gpd (30.9 m³/d)
- TMH20A-400: 8,800 gpd (33.3 m³/d)
- TMH20A-430: 9,500 gpd (35.9 m³/d)
- TMH20A-440: 9,700 gpd (36.7 m³/d)
The datasheet also presents a table containing typical product flow rates, feed spacer thicknesses, a higher salt rejection (99.3%), membrane areas, and diameters for each model. Due to conflicting information regarding product flow rates between the general table and the explicit "Minimum Product Flow Rate" section, See the official PDF for exact tabulated values.
Operating Limits
- Maximum Operating Pressure: 365 psi (2.5 MPa)
- Maximum Feed Water Temperature: 113°F (45℃)
- Maximum Feed Water SDI₁₅: 5
- Feed Water Chlorine Concentration: Not Detactable
- Feed Water pH Range, Continuous Operation: 2-11
- Feed Water pH Range, Chemical Cleaning: 1-12
- Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
- Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)
Mechanical / Hydraulic
The product dimensions are:
- TMH10A: 4 inches (101 mm) diameter, 40 inches (1,016 mm) length.
- TMH20A series elements are 8 inches in diameter and 40 inches (1,016 mm) in length.
- Other internal dimensions shown are 1.05 inches (26 mm) and 0.75 inches (19 mm).
Operating Information
- For the recommended design range, consult the latest technical bulletin, design guidelines, computer design program, or an application specialist.
- Failure to strictly follow the operating limits will void the Limited Warranty.
- Elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and then vacuum packed in oxygen barrier bags.
- Alternatively, elements may be treated with tested feed water solution and vacuum packed with a deoxidant inside.
- To prevent biological growth during short-term storage, shipment, or system shutdown, it is recommended that elements be immersed in a protective solution containing 500 - 1,000 ppm of food-grade sodium bisulfite dissolved in permeate.
- Permeate from the first hour of operation shall be discarded.
- The customer is fully responsible for the effects of chemicals that are incompatible with the elements; their use will void the element Limited Warranty.
Disclaimer
This summary is based on the provided text extract. The original PDF may contain additional figures, footnotes, or revisions not present here. For contractual data, always refer to the specific OEM PDF revision used for your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.