Summary

Product identification

The AE Series consists of proprietary thin-film reverse osmosis (TFM) elements characterized by excellent sodium chloride (NaCl) rejection. These elements are designed for high-quality permeate production from seawater with relatively high Total Dissolved Solids (TDS). AE series membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions, with pressures exceeding 800 psi (5,516 kPa).

Element Specification

Testing conditions for average salt rejection and permeate flow are: 32,000 mg/L NaCl & 5 mg/L Boron solution at 800 psi (5,516 kPa) operating pressure, 77°F (25°C), pH 8.0 and 10% recovery. Average salt rejection is measured after 24 hours of operation. Individual flow rate may vary ±20%.

  • AE-90
    • Average permeate flow: 1875 GPD (7.1 m³/day)
    • Average NaCl rejection: 99.8%
    • Minimum NaCl rejection: 99.5%
    • Minimum Boron Rejection: 92.0%
  • AE-400, 34
    • Average permeate flow: 9000 GPD (34.1 m³/day)
    • Average NaCl rejection: 99.8%
    • Minimum NaCl rejection: 99.5%
    • Minimum Boron Rejection: 92.0%
  • AE-440
    • Average permeate flow: 9900 GPD (37.5 m³/day)
    • Average NaCl rejection: 99.8%
    • Minimum NaCl rejection: 99.5%
    • Minimum Boron Rejection: 92.0%

Element Properties

Element properties are indicative numbers; specific values may vary within normal manufacturing tolerances.

  • AE-90
    • Active area: 90 ft² (8.4 m²)
    • Outer wrap: Fiberglass
    • Part number: 3056660
  • AE-400, 34
    • Active area: 400 ft² (37.2 m²)
    • Outer wrap: Fiberglass
    • Part number: 3056662
  • AE-440
    • Active area: 440 ft² (40.9 m²)
    • Outer wrap: Fiberglass
    • Part number: 3056663

Mechanical / hydraulic

Dimensions and weights are indicative numbers; specific values may vary within normal manufacturing tolerances.

  • AE-90
    • Type: Male
    • Dimensions:
      • A: 40.0 inches (101.6 cm)
      • B: 0.75 inches (1.90 cm)
      • C: 3.9 inches (9.9 cm)
    • Boxed Weight: 9 lbs (4 kg)
  • AE-400, 34
    • Type: Female
    • Dimensions:
      • A: 40.0 inches (101.6 cm)
      • B: 1.125 inches (2.86 cm)
      • C: 7.9 inches (20.1 cm)
    • Boxed Weight: 35 lbs (16 kg)
  • AE-440
    • Type: Female
    • Dimensions:
      • A: 40.0 inches (101.6 cm)
      • B: 1.125 inches (2.86 cm)
      • C: 7.9 inches (20.1 cm)
    • Boxed Weight: 35 lbs (16 kg)

Operating limits

Operating and CIP parameters are indicative numbers; specific values may vary within normal manufacturing tolerances.

  • Typical Operating Pressure: 800 psi (5,516 kPa)
  • Typical Operating Flux: 7-11 GFD (12-19 LMH)
  • Maximum Operating Pressure: 1,200 psi (8,274 kPa)
  • Maximum Temperature:
    • Continuous operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH range:
    • Optimum rejection pH: 7.0-7.5
    • Continuous operation: 2.0-11.0
    • Clean-In-Place (CIP): 1.0 – 12.0 (Refer to Cleaning Guidelines Technical Bulletin TB1194 for CIP details.)
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 50 psi (345 kPa)
  • Chlorine Tolerance: 1,000+ ppm-hours; dechlorination recommended.