Datasheet summary
AG-400 FR H
Engineering summary from PDF text extraction for AG-400 FR H. Verify every value with the OEM datasheet.
Summary
Product identification
The AG FR H Series of thin-film reverse osmosis (RO) elements are designed for challenging brackish water applications requiring high rejection and fouling resistance. These elements combine advanced chemistry and manufacturing to deliver differentiated performance in both ionic rejection and rejection of uncharged or lightly charged species such as silica (SiO₂).
The AG FR H Series membranes have NSF/ANSI/CAN 61 certification for use in municipal applications, including surface water treatment for drinking water, with intent to remove emerging contaminants such as PFAS compounds.
- Membrane: Thin-film membrane (TFM), polyamide
- Model: AG-400 FR H
- Part number: 3187651
Product water
Element Specification (AG-400 FR H)
- Average permeate flow: 11,000 gpd (41.6 m³/day)
- Typical NaCl rejection: 99.8%
- Minimum NaCl rejection: 99.5%
Testing conditions for the above specifications: 2,000 ppm NaCl solution at 225 psi (1,550 kPa) operating pressure, 77°F (25°C), pH 7 and 15% recovery. Individual flow rate may vary ±20%.
Operating limits
- Typical Operating Pressure: 200 psi (1,380 kPa)
- Typical Operating Flux: 10-20 GFD (15-35 LMH)
- Maximum Operating Pressure: 600 psi (4,137 kPa)
- Maximum Temperature:
- Continuous operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH Range:
- Optimum rejection: 7.0-7.5
- Continuous operation: 2.0-11.0
- Clean-In-Place (CIP): 1.0-12.0
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 50 psi (345 kPa)
- Chlorine Tolerance: 1,000+ ppm-hours (dechlorination recommended)
Feed water
- NTU: < 1
- SDI₁₅: < 5
Mechanical / hydraulic
Element Properties (AG-400 FR H)
- Active area: 400 ft² (37.2 m²)
- Outer wrap: Fiberglass
- Feed Spacer: 34 mil
Dimensions and Weights (AG-400 FR H)
- Type: Female
- Dimensions, inches (cm):
- A: 40.0 (101.6)
- B: 1.125 (2.86)
- C: 7.9 (20.1)
- Boxed weight: 40 lbs (18 kg)
Handling and storage
Each RO element is wet tested, preserved in a 1% weight sodium bisulfite solution, and vacuum packed in oxygen barrier bags.
- Storage: Avoid freezing and direct sunlight. The temperature should be below 35°C (95°F).
- After Installation:
- Keep the RO elements wet and use a compatible preservative for storage durations longer than 7 days.
- During initial start-up, discharge the first permeate to drain for 30 minutes.
- Permeate back pressure should not exceed feed pressure at any time.
- Maintain elements in a clean condition, unfouled by particulate matter, precipitates, or biological growth.
- Consider cleaning if the pressure drop increases by 20% or water permeability decreases by 10%. Use only chemicals compatible with the membrane.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.