Datasheet summary
Ag-90 H
Engineering summary from PDF text extraction for Ag-90 H. Verify every value with the OEM datasheet.
Summary
Product identification
The AG H Series consists of high-performance, very high rejection brackish water Reverse Osmosis (RO) elements. These elements are designed for applications requiring the highest levels of rejection, including ultrapure water production and treating high-pressure boiler feed water.
AG H Series elements utilize Thin-film membrane (TFM), polyamide technology and are NSF/ANSI/CAN 61 certified. They are engineered to deliver differentiated performance in ionic rejection and in the rejection of uncharged or lightly charged species like silica.
Element Specification (Based on testing conditions: 2,000 ppm NaCl solution at 225 psi (1,550 kPa) operating pressure, 77°F (25°C), pH 7 and 15% recovery. Average salt rejection after 24 hours of operation. Individual flow rate may vary ±20%.)
- AG-90 H
- Average permeate flow: 2,600 gpd (9.8 m³/day)
- Typical NaCl rejection: 99.8%
- Minimum NaCl rejection: 99.65%
- AG-400 H
- Average permeate flow: 11,000 gpd (41.6 m³/day)
- Typical NaCl rejection: 99.8%
- Minimum NaCl rejection: 99.65%
- AG-440 H
- Average permeate flow: 12,000 gpd (45.4 m³/day)
- Typical NaCl rejection: 99.8%
- Minimum NaCl rejection: 99.65%
Operating limits
- Typical Operating Pressure: 200 psi (1,380 kPa)
- Typical Operating Flux: 10-20 GFD (15-35 LMH)
- Maximum Operating Pressure: 600 psi (4,137 kPa)
- Maximum Temperature:
- Continuous operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH range:
- Optimum rejection: 7.0-7.5
- Continuous operation: 2.0-11.0
- Clean-In-Place (CIP): 1.0-12.0
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 50 psi (345 kPa)
- Chlorine Tolerance: 1,000+ ppm-hours, dechlorination recommended
Feed water
- NTU: < 1
- SDI₁₅: < 5
Mechanical / hydraulic
(Element properties and parameters are indicative; specific values may vary within normal manufacturing tolerances.)
Element Properties
- AG-90 H
- Active area: 90 ft² (8.3 m²)
- Outer wrap: Fiberglass
- Feed Spacer: 31 mil
- Part number: 3194885
- AG-400 H
- Active area: 400 ft² (37.2 m²)
- Outer wrap: Fiberglass
- Feed Spacer: 34 mil
- Part number: 3150329
- AG-440 H
- Active area: 440 ft² (40.9 m²)
- Outer wrap: Fiberglass
- Feed Spacer: 28 mil
- Part number: 3150328
Dimensions and Weights
- AG-90 H (Male)
- Dimensions A: 40.0 inches (101.6 cm)
- Dimensions B: 0.75 inches (1.9 cm)
- Dimensions C: 3.9 inches (9.9 cm)
- Boxed weight: 9 lbs (4 kg)
- AG-400 H (Female)
- Dimensions A: 40.0 inches (101.6 cm)
- Dimensions B: 1.125 inches (2.86 cm)
- Dimensions C: 7.9 inches (20.1 cm)
- Boxed weight: 40 lbs (18 kg)
- AG-440 H (Female)
- Dimensions A: 40.0 inches (101.6 cm)
- Dimensions B: 1.125 inches (2.86 cm)
- Dimensions C: 7.9 inches (20.1 cm)
- Boxed weight: 42 lbs (19 kg)
Handling and Storage
- Treat RO elements with care; do not drop.
- Each RO element is wet tested. 8-inch diameter elements are preserved in a 1% weight sodium bisulfite solution and vacuum packed. 4-inch diameter elements are packaged with oxygen scavenger packets.
- During storage, avoid freezing and direct sunlight. Temperature should be below 35°C (95°F).
- After installation, keep RO elements wet and use a compatible preservative for storage longer than 7 days.
- During initial start-up, discharge the first permeate to drain for 30 minutes.
- Permeate back pressure should not exceed feed pressure.
- Maintain elements in a clean condition, unfouled by particulate matter, precipitates, or biological growth.
- Consider cleaning if pressure drop increases by 20% or water permeability decreases by 10%. Use only compatible chemicals.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.