Datasheet summary
AG HR LF series
Engineering summary from PDF text extraction for AG HR LF series. Verify every value with the OEM datasheet.
Summary
Product identification
The AG HR LF Series is a family of proprietary thin-film reverse osmosis (RO) elements designed for high flux and high sodium chloride (NaCl) rejection. These A-Series membranes are selected for the treatment of impaired water where high rejection is desired. The AG HR LF membrane features a more neutral charge, which helps reduce interactions with potential foulants found in surface water or tertiary effluent.
- Membrane Type: A-Series, Thin-film membrane (TFM)
- Description: High rejection low fouling brackish water RO element
Element Specifications
Performance is based on testing conditions of 2,000 ppm NaCl solution at 225 psi (1,550 kPa) operating pressure, 77°F (25°C), pH 7, and 15% recovery. Average salt rejection is measured after 24 hours of operation. Individual flow rate may vary +25%/-20%.
- AG-90 LF
- Average permeate flow: 1875 gpd (7.1 m³/day)
- Average NaCl rejection: 99.8%
- Minimum NaCl rejection: 99.3%
- AG-400 LF, 34
- Average permeate flow: 10500 gpd (39.7 m³/day)
- Average NaCl rejection: 99.8%
- Minimum NaCl rejection: 99.3%
Element Properties
These properties are indicative numbers; specific values may vary within normal manufacturing tolerances.
- AG-90 LF
- Active area: 90 ft² (8.4 m²)
- Outer wrap: Fiberglass
- Part number: 3056674
- AG-400 LF, 34
- Active area: 400 ft² (37.2 m²)
- Outer wrap: Fiberglass
- Part number: 3056675
Mechanical / Hydraulic
These dimensions and weights are indicative numbers; specific values may vary within normal manufacturing tolerances.
- AG-90 LF (Male)
- A: 40.0 inches (101.6 cm)
- B: 0.75 inches (1.90 cm)
- C: 3.9 inches (9.9 cm)
- Boxed Weight: 9 lbs (4 kg)
- AG-400 LF, 34 (Female)
- A: 40.0 inches (101.6 cm)
- B: 1.125 inches (2.86 cm)
- C: 7.9 inches (20.1 cm)
- Boxed Weight: 35 lbs (16 kg)
Operating limits
These parameters are indicative numbers; specific values may vary within normal manufacturing tolerances.
- Typical Operating Pressure: 200 psi (1,380 kPa)
- Typical Operating Flux: 10-20 GFD (15-35 LMH)
- Maximum Operating Pressure: 600 psi (4,137 kPa)
- Maximum Temperature
- Continuous operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH range
- Optimum rejection: 7.0-7.5
- Continuous operation: 2.0-11.0
- Clean-In-Place (CIP): 1.0-13.0 (Refer to Cleaning Guidelines Technical Bulletin TB1194)
- Maximum Pressure Drop
- Over an element: 15 psi (103 kPa)
- Per housing: 50 psi (345 kPa)
- Chlorine Tolerance: 1,000+ ppm-hours, dechlorination recommended
Feed water
- NTU: < 1
- SDI₁₅: < 5
Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.