Datasheet summary
AG LE
Engineering summary from PDF text extraction for AG LE. Verify every value with the OEM datasheet.
Summary
Product Identification
The AG LE Series of thin-film reverse osmosis (RO) elements are designed for brackish water applications, optimizing energy performance with high rejection. These elements feature a thin-film polyamide membrane.
Element Specification
| Model | Average permeate flow gpd (m³/day) (1) | Typical NaCl rejection (1) | Minimum NaCl rejection (1) |
|---|---|---|---|
| AG8040F-400 LE | 8,500 (32.2) | 99.0% | 98.5% |
| AG8040F-440 LE | 9,100 (34.5) | 99.0% | 98.5% |
(1) Average salt rejection after 24 hours of operation. Individual flow rate may vary with a minimum of 6,800 gpd (25.7 m³/day) for the AG8040F-400 LE and 7,280 gpd (27.6 m³/day) for the AG8040F-440 LE. Testing conditions: 2,000 ppm NaCl solution at 150 psi (1,034 kPa) operating pressure, 77°F (25°C), pH 7 and 15% recovery.
Element Properties
| Model | Active area ft² (m²) | Outer wrap | Part number |
|---|---|---|---|
| AG8040F-400 LE | 400 (37.2) | Fiberglass | 3160987 |
| AG8040F-440 LE | 440 (40.9) | Fiberglass | 3194309 |
Operating Limits
- Typical Operating Pressure: 150 psi (1,034 kPa)
- Maximum Operating Pressure: 600 psi (4,137 kPa)
- Typical Operating Flux: 10-20 GFD (15-35 LMH)
- Maximum Temperature (Continuous operation): 113°F (45°C)
- pH Range:
- Continuous operation: 2.0-11.0
- Clean-In-Place (CIP): 1.0-12.0
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 50 psi (345 kPa)
- Chlorine Tolerance: 1,000+ ppm-hours; dechlorination recommended.
Feed Water
- NTU < 1
- SDI₁₅ < 5
Mechanical / Hydraulic
Dimensions and Weights
| Model | Type | Dimensions, inches (cm) A | Dimensions, inches (cm) B | Dimensions, inches (cm) C | Boxed weight lbs (kg) |
|---|---|---|---|---|---|
| AG8040F-400 LE | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 35 (16) |
| AG8040F-440 LE | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 35 (16) |
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.