Datasheet summary
AP series
Engineering summary from PDF text extraction for AP series. Verify every value with the OEM datasheet.
Summary
Product identification
The AP Series consists of Extreme Low Pressure Brackish Water Reverse Osmosis (RO) elements, utilizing an A-series thin-film membrane (TFM*). These elements are designed for high flux and relatively high sodium chloride rejection, ideal for applications requiring high flow and ultra-low operating pressures such as beverage, light commercial, residential, and general industrial uses.
Element Specifications:
-
Membrane: A-series, thin-film membrane (TFM*)
-
Models:
- AP-90
- Average permeate flow: 2300 gpd (9.1 m³/day)
- Average NaCl rejection: 95%
- Minimum NaCl rejection: 92%
- Active area: 90 ft² (8.4 m²)
- Outer wrap: Fiberglass
- Part number: 3063034
- AP-365
- Average permeate flow: 10,000 gpd (37.9 m³/day)
- Average NaCl rejection: 95%
- Minimum NaCl rejection: 92%
- Active area: 365 ft² (33.9 m²)
- Outer wrap: Fiberglass
- Part number: 3056613
- AP-400
- Average permeate flow: 11,000 gpd (41.6 m³/day)
- Average NaCl rejection: 95%
- Minimum NaCl rejection: 92%
- Active area: 400 ft² (37.1 m²)
- Outer wrap: Fiberglass
- Part number: 3134276
- AP-90
-
Testing Conditions (for average salt rejection and permeate flow): 500 ppm NaCl solution at 75 psi (520 kPa) operating pressure, 77°F (25°C), pH 7 and 15% recovery. Individual flow rate may vary ±20%. Average salt rejection is measured after 24 hours of operation.
Operating limits
- Typical Operating Pressure: 70 psi (483 kPa gage)
- Typical Operating Flux: 10-20 GFD (17-34 LMH)
- Maximum Operating Pressure: 200 psi (1380 kPa gage)
- Maximum Temperature:
- Continuous operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH range:
- Optimum rejection: 7.0-7.5
- Continuous operation: 2.0-11.0
- Clean-In-Place (CIP): 1.0-13.0
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 50 psi (345 kPa)
- Chlorine Tolerance: 1,000+ ppm-hours; dechlorination is recommended.
Feed water
- Turbidity (NTU): < 1
- Silt Density Index (SDI₁₅): < 5
Mechanical / hydraulic
Dimensions and Weights:
- AP-90
- Type: Male
- Dimensions A: 40.0 inches (101.6 cm)
- Dimensions B: 0.75 inches (1.90 cm)
- Dimensions C: 3.9 inches (9.9 cm)
- Boxed Weight: 9 lbs (4 kg)
- AP-365
- Type: Female
- Dimensions A: 40.0 inches (101.6 cm)
- Dimensions B: 1.125 inches (2.86 cm)
- Dimensions C: 7.9 inches (20.1 cm)
- Boxed Weight: 35 lbs (16 kg)
- AP-400
- Type: Female
- Dimensions A: 40.0 inches (101.6 cm)
- Dimensions B: 1.125 inches (2.86 cm)
- Dimensions C: 7.9 inches (20.1 cm)
- Boxed Weight: 35 lbs (16 kg)
Note: Dimensions A, B, and C refer to points indicated on the element dimensions diagrams (Figure 1 and Figure 1b) which are not provided in this text extract.
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual purposes and exact specifications, always refer to the official OEM PDF revision used on your project.
Official datasheet (PDF)