Back to Veolia Membranes
Veolia logo

Datasheet summary

Dairy DK2540C30

Engineering summary from PDF text extraction for Dairy DK2540C30. Verify every value with the OEM datasheet.

Summary

Product identification

The Dairy DK Series consists of D-Series family proprietary thin-film nanofiltration membrane elements, characterized by an approximate molecular weight cut-off of 150-300 Dalton for uncharged organic molecules. Divalent and multivalent anions are preferentially rejected, while monovalent ion rejection depends on feed concentration and composition.

The DK membrane has a minimum rejection of 98% on 2,000 ppm MgSO₄ at 25°C (77°F) and 110psi operating pressure.

These elements are typically used in food-related processes requiring stringent sanitary procedures, including lactose desalting, deacidification, and demineralization of whey or UF permeate. They feature a Durasan* Cage patented outer wrap, a selection of feed spacers, and polysulfone parts.

The Dairy DK elements comply with:

  • FDA Regulations relevant sections of 21CFR
  • EU Framework 1935/2004/EC
  • Halal and Kosher certifications

Membrane type: D-Series, Thin Film Membrane (TFM*)

ModelSpacer mil (mm)Active Area ft² (m²)Part Number
Dairy DK3838C3030 (0.76)75 (7.0)1227618
Dairy DK3838C5050 (1.27)60 (5.6)3161358
Dairy DK3840C3030 (0.76)77 (7.2)1206940
Dairy DK3840C5050 (1.27)58 (5.4)1206942
Dairy DK8038C3030 (0.76)372 (34.6)1226591
Dairy DK8038C5050 (1.27)282 (26.2)1206977
Dairy DK8038C6565 (1.65)220 (20.4)1269441
Dairy DK8040C3030 (0.76)374 (34.7)1229937

Operating limits

  • Typical Operating Pressure: 70-400psi (483-2,757kPa)
  • Typical Operating Flux: 5-20 GFD (8–34 LMH)
  • Maximum Operating Pressure: 600psi (4,137kPa)
  • Maximum Permeate Pressure: 60 psi (413 kPa) (Permeate pressure should never exceed concentrate pressure.)
  • Maximum Temperature: 122°F (50°C)
  • pH Range: 3.0-9.0
  • Recommended Pressure Drop over an element: 12psi (83kPa)
  • Maximum Pressure Drop over an element: 15psi (103kPa)
  • Maximum Pressure Drop per housing: 60psi (414kPa)
  • Chlorine Tolerance: 500ppm-hours (dechlorination recommended)

Product water

  • Clean Water Flux (CWF): 14 GFD (24 LMH) @ 110psi. CWF is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. CWF can vary ±25%.

Mechanical / Hydraulic

Element dimensions are referenced by figures (Figure 1 for 8040, Figure 2 for all others) which are not included in this extract.

ModelA inches (cm)B inches (cm)C inches (cm)Boxed Weight lbs (kg)
Dairy DK3838C38.00 (96.5)0.833 (2.12)3.79 (9.6)9 (5)
Dairy DK3840C38.75 (98.4)0.833 (2.12)3.79 (9.6)9 (5)
Dairy DK8038C38.00 (96.5)1.125 (2.86)7.91 (20.1)35 (16)
Dairy DK8040C40.00 (101.6)1.125 (2.86)7.91 (20.1)35 (16)

Cleaning Parameters

Limits for Nanofiltration Membranes during Clean-In-Place (CIP):

TemperaturepH MinimumpH Maximum
50°C (122°F)2.011.0
50°C (122°F)2.010.5
45°C (113°F)2.011.0
35°C (95°F)1.511.5
25°C (77°F)1.011.5

Note: CIP at pH 11 and 50°C is acceptable for heavily fouled systems. For optimum membrane element lifetime, pH 10.5 at 50°C (122°F) is recommended for daily CIP protocol.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.