Back to Veolia Membranes
Veolia logo

Datasheet summary

PW series

Engineering summary from PDF text extraction for PW series. Verify every value with the OEM datasheet.

Summary

Product identification

The Dairy PW Series are polyethersulfone ultrafiltration membrane elements, characterized by a 20,000 molecular weight cut-off. They are typically used for protein concentrate up to 20% from milk and sweet whey (not suitable for acid whey). These elements feature a Durasan* Cage patented outer wrap and polysulfone parts.

Certifications

The Dairy PW elements comply with:

  • FDA Regulations relevant sections of 21CFR
  • EU Framework 1935/2004/EC
  • Halal & Kosher certification

Element Specifications

ModelSpacer mil (mm)Active area ft² (m²)Outer WrapPart Number
DAIRY PW3838C3030 (0.76)69 (6.4)Cage1228024
DAIRY PW3838C5050 (1.27)55 (5.1)Cage1229303
DAIRY PW6338C3030 (0.76)217 (20.2)Cage1207392
DAIRY PW6338C5050 (1.27)168 (15.6)Cage1207393
DAIRY PW6338C6565 (1.65)129 (12.0)Cage1223985
DAIRY PW8038C3030 (0.76)345 (32.0)Cage1230789
DAIRY PW8038C5050 (1.27)263 (24.4)Cage1230680

Mechanical / Hydraulic

Dimensions and Weight

ModelDimensions, inches (cm)Boxed Weight lbs (kg)
AB
DAIRY PW383838.0 (96.5)0.833 (2.12)
DAIRY PW583838.0 (96.5)1.138 (2.89)
DAIRY PW633838.0 (96.5)1.138 (2.89)
DAIRY PW803838.0 (96.5)1.125 (2.86)

Operating limits

  • Typical Operating Pressure: 80-135 psig (555 – 931 kPa)
  • Typical Operating Flux: 10-25 GFD (15-40 LMH)
  • Clean Water Flux (CWF): 59 GFD (100 LMH) @ 30 psi and 50°C. CWF is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. It is important to monitor CWF after each cleaning cycle to determine if the system is being cleaned effectively. CWF can vary ± 25%.
  • Maximum Operating Pressure: 200 psig (1,379 kPa)
  • Maximum Temperature: Continuous operation: 122°F (50°C)
  • Operating pH Range: 2.0-10.0
  • Maximum Pressure Drop:
    • Over an element: 12 psig (83 kPa)
    • Per housing: 50 psig (345 kPa)
  • Chlorine Tolerance: 5,000+ ppm-days

CIP and Disinfection Parameters

TemperaturepH MinimumpH Maximum
< 50°C (122°F)1.511.5
< 45°C (113°F)1.511.5
< 35°C (95°F)111.5
< 25°C (77°F)112
  • Recommended chlorine concentration and contact time at a maximum temperature of 50°C (120°F) is 180 ppm for 20 minutes MAXIMUM during chlorine caustic cycle.
  • pH must be stabilized at 10.5 - 11.0 before chlorine addition.
  • Membrane element surface must be free of catalyser presence such as iron or other metals. With oxidizers like chlorine or hydrogen peroxide, they accelerate membrane degradation.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.