Back to Veolia Membranes
Veolia logo

Datasheet summary

DL series

Engineering summary from PDF text extraction for DL series. Verify every value with the OEM datasheet.

Summary

Product identification

The DL Series consists of industrial high-flow nanofiltration elements featuring D-Series Thin-Film Membranes (TFM*). These membranes are characterized by an approximate molecular weight cut-off of 150-300 Dalton for uncharged organic molecules. They preferentially reject divalent and multivalent anions, while monovalent ion rejection is dependent upon feed concentration and composition. Since monovalent ions pass through the membrane, they do not contribute to osmotic pressure, allowing systems to operate at lower feed pressures than reverse osmosis (RO) systems.

Typical applications include dye removal/concentration, sodium chloride diafiltration, and metals recovery.

Element Specifications

Testing conditions for average permeate flow and MgSO₄ rejection are: 2,000 ppm MgSO₄ solution at 110 psi (760 kPa) operating pressure, 77°F (25°C), and 15% recovery. Average salt rejection is measured after 24 hours of operation. Individual flow rates may vary ±25%.

ModelAverage permeate flow GPD (m³/day)Average MgSO₄ rejectionSpacer mil (mm)Active area ft² (m²)Outer wrapPart number
DL2540C30610 (2.3)96 %30 (0.76)25 (2.3)Cage3028456
DL2540C50430 (1.6)96 %50 (1.27)18 (1.7)Cage1207015
DL2540F30650 (2.5)96 %30 (0.76)28 (2.6)Fiberglass1207018
DL2540F50450 (1.7)96 %50 (1.27)22 (2.0)Fiberglass1207019
DL4040C302,400 (9.0)96 %30 (0.76)89 (8.2)Cage1207030
DL4040C501,800 (6.8)96 %50 (1.27)67 (6.2)Cage1207028
DL4040F302,400 (9.1)96 %30 (0.76)85 (7.9)Fiberglass3050068
DL4040F501,800 (6.8)96 %50 (1.27)66 (6.1)Fiberglass3050067
DL8040C3010,200 (38.6)96 %30 (0.76)374 (34.7)Cage1207040
DL8040C508,200 (31.0)96 %50 (1.27)300 (27.9)Cage1207041
DL8040F3010,200 (38.6)96 %30 (0.76)364 (33.8)Fiberglass1207048
DL8040F508,200 (31.0)96 %50 (1.27)284 (26.4)Fiberglass1207049

Mechanical / hydraulic

DL4040C** elements do not feature a brine seal.

ModelDimensions, inches (cm) AB (1)CBoxed Weight lbs. (kg)
DL2540F**40.0 (101.6)0.75 (1.90) OD2.4 (6.1)4 (1.8)
DL2540C**40.0 (101.6)0.75 (1.90) OD2.4 (6.1)4 (1.8)
DL4040C**40.0 (101.6) (2)0.625 (1.59)3.9 (9.9)9 (4.1)
DL4040F**40.0 (101.6)0.75 (1.90) OD3.9 (9.9)9 (4.1)
DL8040C**40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)
DL8040F**40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)

(1) Internal diameter unless specified OD (outside diameter). (2) Includes the interconnector.

Operating limits

  • Typical Operating Flux: 5 – 20 GFD (8 – 34 LMH)
  • Maximum Operating Pressure:
    • 600 psi (4,137 kPa) if T < 95°F (35°C)
    • 435 psi (3,000 kPa) if T > 95°F (35°C)
  • Maximum Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH Range:
    • Continuous Operation: 3-9
    • Clean-In-Place (CIP): 2-11
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 60 psi (414 kPa)
  • Chlorine Tolerance: 500 ppm hours, dechlorination recommended.