Datasheet summary
Duracid NF2540F30
Engineering summary from PDF text extraction for Duracid NF2540F30. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: Duracid Series Industrial acid stable nanofiltration elements
- Membrane Type: Proprietary thin-film nanofiltration membrane, Duracid, Thin-film membrane (TFM*)
- Molecular Weight Cut-Off: Approximately 150-200 Dalton for uncharged organic molecules
- Key Characteristics:
- Engineered to operate continuously under extreme acid conditions (pH at or below zero).
- Divalent and multivalent ions are preferentially rejected.
- Monovalent ions and mineral acids commonly have full transmission (transmission can vary depending upon feed concentration and composition).
- Mineral acids and monovalent ions have minor contribution to osmotic pressure.
- Applications: Acid purification, metals concentration in low pH streams.
- Construction Materials: Patented feed spacers, polysulfone parts, fiberglass outer wrap. All materials of construction are low pH tolerant.
- Features & Benefits:
- Extreme low pH stability
- 100% wet testing Quality Assurance
- Durable construction
- High temperature compatibility
- Markets:
- Metal Surface Treatment / Coating / Galvanic
- Heap Leaching Process in Mining
- Phosphate-based Chemical Production
- Spent Acid Recovery
Operating limits
- Typical Operating Pressure: 400 – 800 psi (2758 – 5516 kPa)
- Maximum Operating Pressure:
- 1200 psi (8,273 kPa) @ T < 77°F (25°C)
- 800 psi (5,515 kPa) @ T < 122°F (50°C)
- 600 psi (4,137 kPa) @ T < 158°F (70°C)
- Maximum Temperature:
- Continuous operation: 158°F (70°C)
- Clean-In-Place (CIP): 158°F (70°C)
- Continuous pH: < 10 (up to 70°C)
- CIP pH:
- < 11.0 @ T < 113°F (45°C)
- < 10.5 @ T < 131⁰F (55°C)
- < 10.0 @ T < 158°F (70°C)
- Chlorine Tolerance: 500 ppm x hours (dechlorination recommended)
Feed water
- Pre-conditioning: A 5-minute pure water flush at a minimum pressure of 500 psig (3447 kPa) at ambient temperature is required to optimize flow and rejection performance.
- Typical Process Streams (Acid Concentration):
- HCl: 5-37%
- H₂SO₄: 5-20%
- H₃PO₄: 5-20%
- Membrane Metal Rejection (Based on flat sheet test conducted at 25°C (77°F) under 400 psig operating pressure in a dead-end filtration mode):
- Fe²⁺ (2000 ppm): >90% in 5% H₂SO₄, >85% in 5% H₃PO₄
- Al³⁺ (2000 ppm): >90% in 5% H₂SO₄, >85% in 5% H₃PO₄
- Cu²⁺ (2000 ppm): >90% in 5% H₂SO₄, >85% in 5% H₃PO₄
- Cd²⁺ (100 ppm): >90% in 5% H₂SO₄, >85% in 5% H₃PO₄
- Ni⁺ (2000 ppm): >90% in 5% H₂SO₄, >85% in 5% H₃PO₄
Product water
- Typical Operating Flux: 5 – 14 GFD (9 – 24 LMH)
- Clean Water Flux (CWF): 10-19 GFD (17-32 LMH) @ 225 psi (1551 kPa). (CWF is the rate of water permeability through the membrane after cleaning at reproducible temperature and pressure. It can vary ±25%.)
- Average MgSO₄ Rejection: 98% (Measured on pre-conditioned elements after 24 hours operation; testing conditions: 2,000 ppm MgSO₄ solution at 110 psi (760 kPa) operating pressure, 77°F (25°C), 15% recovery.)
Mechanical / hydraulic
- Model: Duracid NF2540F30
- Dimensions (Male, Figure 1):
- A: 40.0 inches (101.6 cm)
- B: 0.75 inches (1.9 cm)
- C: 2.4 inches (6.1 cm)
- Boxed Weight: 4 lbs (1.8 kg)
- Spacer: 30 mil (0.76 mm)
- Active Area: 28 ft² (2.6 m²)
- Outer Wrap: Fiberglass
- Part Number: 1231058
- Average Permeate Flow (measured on pre-conditioned elements after 24 hours operation):
- 155 gpd (0.6 m³/day) (Testing conditions: 2,000 ppm MgSO₄ solution at 110 psi (760 kPa) operating pressure, 77°F (25°C), 15% recovery.)
- 560 gpd (2.1 m³/day) (Testing conditions: 3% glucose solution at 440 psi (3034 kPa) operating pressure, 77°F (25°C), 15% recovery.)
- Maximum Crossflow: 7 gpm (1.6 m³/hr)
- Dimensions (Male, Figure 1):
- Maximum Pressure Drops:
- Over an element:
- 15 psig (103 kPa) for 0°C-50°C
- 7 psig (48 kPa) for 51°C-70°C
- Per housing:
- 60 psig (414 kPa) for 0°C-50°C
- 30 psig (207 kPa) for 51°C-70°C
- Over an element: