Back to Veolia Membranes
Veolia logo

Datasheet summary

GE series

Engineering summary from PDF text extraction for GE series. Verify every value with the OEM datasheet.

Summary

Product identification

The GE Series consists of industrial ultrafiltration (UF) elements utilizing a proprietary G-Series Thin-Film Membrane (TFM). These elements are characterized by a molecular weight cutoff (MWCO) of 1,000 on polyethylene glycol and feature a smooth, fouling-resistant membrane surface.

GE elements are used for applications such as surface water pretreatment, color/TOC reduction, and chemical purification.

Product specifications

ModelAverage permeate flow gpd (m³/day)MWCO (Dalton)Spacer mil (mm)Active area ft² (m²)Outer wrapPart number
GE2540F30740 (2.8)1,00030 (0.76)28 (2.6)Fiberglass1207086
GE2540F50500 (1.9)1,00050 (1.27)22 (2.0)Fiberglass1207087
GE4040C502,000 (7.6)1,00050 (1.27)67 (6.2)Cage1207091
GE4040F302,600 (9.8)1,00030 (0.76)85 (7.9)Fiberglass3050063
GE8040F3010,000 (37.8)1,00030 (0.76)364 (33.8)Fiberglass1207098
GE8040F507,300 (27.6)1,00050 (1.27)284 (26.4)Fiberglass1207096

Flux specifications are based on fouling-free water at 410 psi (2,827 kPa) operating pressure, 77°F (25°C), and 10% recovery. Individual element flux may vary ± 25%.

Note: GE4040C elements do not feature a brine seal.

Mechanical / hydraulic

Dimensions and Weight

ModelTypeDimensions, inches (cm) ADimensions, inches (cm) BDimensions, inches (cm) CBoxed Weight lbs (kg)
GE2540F**Male40.0 (101.6)0.751.904 (1.8)
GE4040C**Female40.0 (101.6)0.625 (1.59)3.9 (9.9)9 (4.1)
GE4040F**Male40.0 (101.6)0.75 (1.90)3.9 (9.9)9 (4.1)
GE8040F**Female40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)
  • Dimension 'A' for GE4040C** elements includes the interconnector.
  • See the official PDF for Element Dimensions Diagrams (Figure 1: Female, Figure 2: Male).

Operating limits

  • Typical Operating Flux: 5-20 GFD (8-34 LMH)
  • Maximum Operating Pressure: 400 psi (2,760 kPa)
  • Maximum Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH Range:
    • Continuous Operation: 2.0-10.0
    • Clean-In-Place (CIP): 1.0-13.0 (Refer to Cleaning Guidelines Technical Bulletin TB1194.)
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 60 psi (414 kPa)
  • Chlorine Tolerance: 20-50 ppm days