Datasheet summary
GE series
Engineering summary from PDF text extraction for GE series. Verify every value with the OEM datasheet.
Summary
Product identification
The GE Series consists of industrial ultrafiltration (UF) elements utilizing a proprietary G-Series Thin-Film Membrane (TFM). These elements are characterized by a molecular weight cutoff (MWCO) of 1,000 on polyethylene glycol and feature a smooth, fouling-resistant membrane surface.
GE elements are used for applications such as surface water pretreatment, color/TOC reduction, and chemical purification.
Product specifications
| Model | Average permeate flow gpd (m³/day) | MWCO (Dalton) | Spacer mil (mm) | Active area ft² (m²) | Outer wrap | Part number |
|---|---|---|---|---|---|---|
| GE2540F30 | 740 (2.8) | 1,000 | 30 (0.76) | 28 (2.6) | Fiberglass | 1207086 |
| GE2540F50 | 500 (1.9) | 1,000 | 50 (1.27) | 22 (2.0) | Fiberglass | 1207087 |
| GE4040C50 | 2,000 (7.6) | 1,000 | 50 (1.27) | 67 (6.2) | Cage | 1207091 |
| GE4040F30 | 2,600 (9.8) | 1,000 | 30 (0.76) | 85 (7.9) | Fiberglass | 3050063 |
| GE8040F30 | 10,000 (37.8) | 1,000 | 30 (0.76) | 364 (33.8) | Fiberglass | 1207098 |
| GE8040F50 | 7,300 (27.6) | 1,000 | 50 (1.27) | 284 (26.4) | Fiberglass | 1207096 |
Flux specifications are based on fouling-free water at 410 psi (2,827 kPa) operating pressure, 77°F (25°C), and 10% recovery. Individual element flux may vary ± 25%.
Note: GE4040C elements do not feature a brine seal.
Mechanical / hydraulic
Dimensions and Weight
| Model | Type | Dimensions, inches (cm) A | Dimensions, inches (cm) B | Dimensions, inches (cm) C | Boxed Weight lbs (kg) |
|---|---|---|---|---|---|
| GE2540F** | Male | 40.0 (101.6) | 0.75 | 1.90 | 4 (1.8) |
| GE4040C** | Female | 40.0 (101.6) | 0.625 (1.59) | 3.9 (9.9) | 9 (4.1) |
| GE4040F** | Male | 40.0 (101.6) | 0.75 (1.90) | 3.9 (9.9) | 9 (4.1) |
| GE8040F** | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 29 (13.2) |
- Dimension 'A' for GE4040C** elements includes the interconnector.
- See the official PDF for Element Dimensions Diagrams (Figure 1: Female, Figure 2: Male).
Operating limits
- Typical Operating Flux: 5-20 GFD (8-34 LMH)
- Maximum Operating Pressure: 400 psi (2,760 kPa)
- Maximum Temperature:
- Continuous Operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH Range:
- Continuous Operation: 2.0-10.0
- Clean-In-Place (CIP): 1.0-13.0 (Refer to Cleaning Guidelines Technical Bulletin TB1194.)
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 60 psi (414 kPa)
- Chlorine Tolerance: 20-50 ppm days