Back to Veolia Membranes
Veolia logo

Datasheet summary

Industrial RO HP series

Engineering summary from PDF text extraction for Industrial RO HP series. Verify every value with the OEM datasheet.

Summary

Product identification

The Industrial RO HP Series are ultra-high-pressure reverse osmosis elements featuring a proprietary A-Series thin-film membrane for high salt retention. The Industrial RO5 and RO7 HP elements are designed to operate up to 100 bar, utilizing a special element and membrane design. They are typically used for industrial brines to achieve very high salt concentrations in the retentate, improving the efficiency of Zero Liquid Discharge (ZLD) or Minimal Liquid Discharge (MLD) systems. These elements are also recommended for salt recovery in industrial process or waste streams. They incorporate a 35mil spacer in an ultra-high-pressure compatible element assembly.

Element specifications

(1) Average salt rejection after 24h operation. Individual flow rate may vary ±25%. (2) Testing conditions:

  • INDUSTRIAL RO5: 2,000 ppm NaCl solution at 225psi (1,550kPa) operating pressure, 77°F, pH 7.5 and 15% recovery.
  • INDUSTRIAL RO7: 500 ppm NaCl solution at 75psi (520kPa) operating pressure, 77°F, pH 7.5 and 15% recovery.
ModelAverage permeate flow gpd (m³/day)Average NaCl rejectionMinimum NaCl rejection
INDUSTRIAL RO5 HP 4040F352,200 (8.3)99.5%99.0%
INDUSTRIAL RO5 HP 8040F359,200 (34.8)99.5%99.0%
INDUSTRIAL RO7 HP 4040F352,200 (8.3)92.0%90.0%
INDUSTRIAL RO7 HP 8040F359,200 (34.8)92.0%90.0%

Mechanical / hydraulic

(3) Element properties and parameters are indicative numbers. Specific values by element may vary within normal element manufacturing tolerances.

Element properties

ModelSpacer mil (mm)Active area ft² (m²)Outer wrapPart number
INDUSTRIAL RO5 HP 4040F3535 (0.89)75 (7.0)Fiberglass3154755
INDUSTRIAL RO5 HP 8040F3535 (0.89)330 (30.7)Fiberglass3153541
INDUSTRIAL RO7 HP 4040F3535 (0.89)75 (7.0)Fiberglass3169019
INDUSTRIAL RO7 HP 8040F3535 (0.89)330 (30.7)Fiberglass3169018

Dimensions and Weight

ModelTypeDimensions, inches (cm) ADimensions, inches (cm) BDimensions, inches (cm) CBoxed Weight lbs. (kg)
4040FMale40.0 (101.6)0.75 (1.90)3.9 (9.9)11 (5)
8040FFemale40.0 (101.6)1.125 (2.86)7.9 (20.1)35 (16)

Operating limits

  • Typical Operating Flux: 5 - 20 GFD (8 – 34 LMH)
  • Maximum Temperature:
    • Continuous operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH Range:
    • Optimum rejection: 7.0 – 7.5
    • Continuous operation: 2.0 - 11.0
    • Clean-In-Place (CIP): 1.0 - 13.0 (4)
  • Maximum Pressure Drop:
    • Over an element: 15psi (103kPa)
    • Per housing: 60psi (414kPa)
  • Chlorine Tolerance: 500+ ppm hours, dechlorination recommended

Maximum Operating Pressure

TemperatureMaximum Operating Pressure
< 95°F (35°C)1,500psi (10,342kPa)
< 104°F (40°C)1,000psi (6,897kPa)
< 113°F (45°C)700psi (4,828kPa)
< 122°F (50°C)600psi (4,137kPa)

Feed water

  • NTU: < 1
  • SDI₁₅: < 5