Datasheet summary
JX series
Engineering summary from PDF text extraction for JX series. Verify every value with the OEM datasheet.
Summary
Product identification
JX Series industrial microfiltration elements are designed for process stream clarification, including suspended solids removal.
- Membrane: J-Series, Polyvinylidene Fluoride
- Pore-size: 0.3 micron
Element Specifications:
- JX2540F30
- Spacer: 30 mil (0.76 mm)
- Active area: 28 ft² (2.6 m²)
- Outer wrap: Fiberglass
- Part number: 1207253
- JX2540F50
- Spacer: 50 mil (1.27 mm)
- Active area: 22 ft² (2.0 m²)
- Outer wrap: Fiberglass
- Part number: 1207252
- JX4040C30
- Spacer: 30 mil (0.76 mm)
- Active area: 82 ft² (7.6 m²)
- Outer wrap: Cage
- Part number: 1207264
- JX4040F30
- Spacer: 30 mil (0.76 mm)
- Active area: 79 ft² (7.3 m²)
- Outer wrap: Fiberglass
- Part number: 3049975
- JX4040F50
- Spacer: 50 mil (1.27 mm)
- Active area: 62 ft² (5.8 m²)
- Outer wrap: Fiberglass
- Part number: 3049974
- JX8040F30
- Spacer: 30 mil (0.76 mm)
- Active area: 340 ft² (31.6 m²)
- Outer wrap: Fiberglass
- Part number: 1207283
- JX8040F50
- Spacer: 50 mil (1.27 mm)
- Active area: 269 ft² (25.0 m²)
- Outer wrap: Fiberglass
- Part number: 1207284
Note: 4040C elements do not feature brine seal.
Mechanical / hydraulic
Dimensions and Weight:
- JX2540F**
- Type: Male
- Dimensions, inches (cm): A=40.0 (101.6), B=0.75 (1.90), C=2.4 (6.1)
- Boxed Weight: 4 lbs (1.8 kg)
- JX4040C**
- Type: Female
- Dimensions, inches (cm): A=40.0 (101.6), B=0.625 (1.59), C=3.9 (9.9)
- Boxed Weight: 9 lbs (4.1 kg)
- JX4040F**
- Type: Male
- Dimensions, inches (cm): A=40.0 (101.6), B=0.75 (1.90), C=3.9 (9.9)
- Boxed Weight: 9 lbs (4.1 kg)
- JX8040F**
- Type: Female
- Dimensions, inches (cm): A=40.0 (101.6), B=1.125 (2.86), C=7.9 (20.1)
- Boxed Weight: 29 lbs (13.2 kg)
Operating limits
- Typical Operating Flux: 5-20 GFD (8-34 LMH)
- Maximum Operating Pressure: 100 psi (700 kPa)
- Maximum Temperature:
- Continuous Operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH Range:
- Continuous Operation: 2.0-10.0
- Clean-In-Place (CIP): 1.0-13.0
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 60 psi (414 kPa)
- Chlorine Tolerance: 5,000+ ppm-days
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.