Datasheet summary
PT series
Engineering summary from PDF text extraction for PT series. Verify every value with the OEM datasheet.
Summary
Product identification
The PT series consists of Industrial Ultrafiltration Elements made of Polyethersulfone (PES) membrane material. These elements are characterized by a 5,000 molecular weight cut-off.
Element Specification
- Membrane: P-Series, Polyethersulfone
- Model PT8040C50:
- Spacer: 50 mil (1.27 mm)
- Active area: 264 ft² (24.5 m²)
- Outer wrap: Cage
- Part number: 1240574
- Model PT8040F30:
- Spacer: 30 mil (0.76 mm)
- Active area: 340 ft² (31.6 m²)
- Outer wrap: Fiberglass
- Part number: 1229772
Dimensions and Weight
- Model: PT8040*
- Type: Female
- Dimensions, inches (cm):
- A: 40.0 (101.6)
- B: 1.125 (2.86)
- C: 7.9 (20.1)
- Weight: 35 lbs (15.9 kg)
Operating limits
- Typical Operating Flux: 5 – 20 GFD (8 – 34 LMH)
- Maximum Operating Pressure: 200 psi (1,379 kPa)
- Maximum Temperature:
- Continuous Operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- pH range:
- Continuous Operation: 2.0-10.0
- Clean-In-Place (CIP): 1.0-13.0 (Refer to Cleaning Guidelines Technical Bulletin TB1194EN)
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 60 psi (414 kPa)
- Chlorine Tolerance: 5,000 ppm days
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.