Back to Veolia Membranes
Veolia logo

Datasheet summary

SE series

Engineering summary from PDF text extraction for SE series. Verify every value with the OEM datasheet.

Summary

Product identification

The SE Series comprises industrial high-rejection brackish water reverse osmosis (RO) elements. These elements feature S-Series, thin-film reverse osmosis (TFM*) membrane technology, characterized by high sodium chloride rejection and a smooth, fouling-resistant membrane surface.

SE elements are designed for brackish water desalination and process stream concentration. They are constructed with either a fiberglass or a patented Durasan* cage outer wrap, 30mil or 50mil spacers, and polysulfone or Noryl plastic parts.

Element Specification

  • SE2540F30
    • Average permeate flow: 550 gpd (2.1 m³/day)
    • Average NaCl rejection: 99%
    • Minimum NaCl rejection: 97.5%
    • Spacer: 30 mil (0.76 mm)
    • Active area: 28 ft² (2.6 m²)
    • Outer wrap: Fiberglass
    • Part number: 1207431
  • SE2540F50
    • Average permeate flow: 370 gpd (1.4 m³/day)
    • Average NaCl rejection: 99%
    • Minimum NaCl rejection: 97.5%
    • Spacer: 50 mil (1.27 mm)
    • Active area: 22 ft² (2.0 m²)
    • Outer wrap: Fiberglass
    • Part number: 1207427
  • SE8040C30
    • Average permeate flow: 8,500 gpd (32.2 m³/day)
    • Average NaCl rejection: 99%
    • Minimum NaCl rejection: 97.5%
    • Spacer: 30 mil (0.76 mm)
    • Active area: 374 ft² (34.7 m²)
    • Outer wrap: Cage
    • Part number: 1207488

Testing conditions (for listed rejection and flow rates): 2,000 ppm NaCl solution at 425 psi (2,930 kPa) operating pressure, 77°F (25°C), pH 6.5 and 15% recovery. Average salt rejection is measured after 24 hours of operation. Individual flow rates may vary ±25%.

Mechanical / hydraulic

Dimensions and Weight

  • SE2540F** (Figure 2: Element Dimensions Diagram (Male))
    • Dimensions:
      • A: 40.0 inches (101.6 cm)
      • B: 0.75 inches (1.9 cm)
      • C: 2.4 inches (6.1 cm)
    • Boxed weight: 4 lbs (1.8 kg)
  • SE8040C** (Figure 1: Element Dimensions Diagram (Female))
    • Dimensions:
      • A: 40.0 inches (101.6 cm)
      • B: 1.125 inches (2.86 cm)
      • C: 7.9 inches (20.1 cm)
    • Boxed weight: 35 lbs (15.9 kg)

Operating limits

  • Typical Operating Flux: 5-20 GFD (8-34 LMH)
  • Maximum Operating Pressure:
    • 600 psi (4,137 kPa) if T < 95°F (35°C)
    • 435 psi (3,000 kPa) if T > 95°F (35°C)
  • Maximum Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH Range:
    • Optimum rejection range: 5.5-7.0
    • Continuous Operation: 2.0-11.0
    • Clean-In-Place (CIP): 1.0-11.5
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 60 psi (414 kPa)
  • Chlorine Tolerance: 500+ ppm-hours; dechlorination is recommended.

Feed water