Back to Vontron Membranes
Vontron logo

Datasheet summary

HP 2012 100

Engineering summary from PDF text extraction for HP 2012 100. Verify every value with the OEM datasheet.

Summary

Product identification

The HP2012-100 is a Helixfil Series Reverse Osmosis Membrane Element developed by VONTRON. It is designed for treating low-salinity water resources.

Application

This RO element is applicable for:

  • Treatment of low-salinity water sources such as tap water and well water.
  • Water purifying devices for residences, hospitals, and laboratories.
  • Centralized water supply and underground water sources. The element operates under extra-low pressure conditions.

Product Performance

ModelPermeate Flow GPD(m³/d)Rejection Rate (%)Min. Rejection (%)
HP2012-100100(0.38)9897
  • Permeate flow variation: ±15%
  • Rejection rate variation: ±2%

Performance is tested under the following conditions:

  • Testing Pressure: 60 psi (0.41 MPa)
  • Temperature of Testing Solution: 25℃
  • Concentration of Testing Solution (NaCl): 250 ppm
  • pH of Testing Solution: 6.5~8.5
  • Recovery of Single Element: 60 %

Mechanical / Hydraulic

Product dimensions are provided below:

DimensionValue (mm)
A298
B48
C17
D115
D220

Important Information

  • Preservation:
    • Dry membrane elements leave the factory without preservation solution. They must be maintained wet after soaking.
    • Wet membrane elements contain 1.0% sodium bisulfite as preservation solution. In winter, 10% propylene glycol antifreeze is added. They are vacuum packaged.
    • When wet membrane elements are not used for a long time, preservation solution is needed to soak them.
  • Initial Use:
    • It is recommended to flush the membrane for 15-25 minutes at low pressure, followed by 60-90 minutes at high pressure (water flow not less than 50% of the system design water flow). Soaking overnight is not suitable during this initial flush.
    • Permeate water and concentrated water produced within the first hour of initial operation must be discharged.
  • Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
  • Warranty: The operating limits and operational guidelines specified herein are part of the limitations of the three-year warranty on the membrane element.
  • Manual: Refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation of membrane elements.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project. Product performance may vary under different conditions, and this information is for reference only.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.