  • Model: HT3-2012-150
  • Series: High TDS Series
  • Application: Designed for treating high TDS (up to 4000 ppm) water resources. This element can effectively remove organic matter, microorganisms, viruses, metal ions, radioactive particles, and carcinogens from water.
  • Uses:
    • Residential water purifiers
    • Hospital and laboratory water purification devices
    • Centralized water supply, underground water, and other water sources

Product Performance

  • Testing Conditions:
    • Testing Pressure: 60 psi (0.41 MPa)
    • Temperature of Testing Solution: 25℃
    • Concentration of Testing Solution (NaCl): 250 ppm
    • pH of Testing Solution: 6.5~8.5
    • Recovery of Single Element: 15 %
  • Performance Values (nominal):
    • Permeate Flow: 150 GPD (0.56 m³/d)
    • Rejection Rate: 98%
    • Min. Rejection: 97%
  • Variations:
    • Permeate flow: ±15%
    • Rejection Rate: ±2%

Feed water

  • Maximum TDS (design basis): 4000 ppm

Mechanical / Hydraulic

The product size dimensions are provided as:

  • A: 298 mm
  • B: 48 mm
  • C: 17 mm
  • D1: 21 mm
  • D2: 21 mm

General Guidelines

  • Preservation: Dry membrane elements leave the factory without preservation solution, but must be kept wet after initial soaking. Wet membrane elements contain 1.0% sodium bisulfite (with 10% propylene glycol antifreeze in winter) as a preservation solution for storage. If wet elements are not used for a long time, a preservation solution is needed.
  • Initial Flushing: When first used, it is recommended to flush the element for 15-25 minutes at low pressure, followed by 60-90 minutes at high pressure (water flow should not be less than 50% of the system design flow). The permeate water and concentrated water produced during the first hour of initial operation should be discharged.
  • Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
  • Product Manual: Refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation of membrane elements.
  • Warranty: The operating limits and operational guidelines presented in this technical information are part of the limitations for the three-year warranty on the membrane element.

Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or revisions not present in this extract. Contractual data for any project must match the specific OEM PDF revision used for that project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.