ULP1810 75
Engineering summary from PDF text extraction for ULP1810 75. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: ULP1810-75
- Series: ULP Series
- Description: Ultra Low Pressure Membrane Elements
- Application:
- Designed for treatment of water resources containing oxidant substances and high microbe contaminations.
- Applicable to water purifying devices for residence, hospital, and laboratory.
- Used to treat centralized water supply, underground water, and other water sources.
Performance Specifications (under test conditions)
Test Conditions
- Testing Pressure: 60 psi (0.41 MPa)
- Temperature of Testing Solution: 25 ℃
- Concentration of Testing Solution (NaCl): 250 ppm
- pH of Testing Solution: 6.5~8.5
- Recovery of Single Element: 15 %
Performance Data
- Model: ULP1810-75
- Permeate Flow: 75 GPD (0.28 m³/d)
- Rejection Rate: 98 %
- Min. Rejection: 96 %
Note on variation:
- Each membrane element may have ±15% variation of permeate flow.
- Rejection Rate ±2%.
Mechanical / Hydraulic
The following dimensions are provided:
- A: 256 mm
- B: 44 mm
- C: 17 mm
- D1: 21 mm
- D2: 21 mm
Operational Guidelines & Preservation
- Preservation Solution:
- Dry membrane elements leave the factory with no preservation solution, vacuum packaged.
- Wet membrane elements leave the factory with 1.0% sodium bisulfite (with 10% propylene glycol antifreeze added in winter) as the preservation solution, vacuum packaged.
- Storage:
- Dry membrane elements must always be maintained wet after soaking.
- Wet membrane elements not used for a long time require soaking in preservation solution.
- Initial Flushing Procedure:
- Flush for 15-25 minutes at low pressure (not suitable for soaking or overnight soaking).
- Then flush for 60-90 minutes at high pressure (water flow should not be less than 50% of the system design water flow).
- The permeate water and concentrated water produced within the first hour of initial operation must be discharged.
- Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
- Warranty: The operating limits and operational guidelines provided are part of the limitations of the three-year warranty on the membrane element.
- Manual: Refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation of membrane elements.
Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. For contractual data and complete information, the specific OEM PDF revision used on the project should be consulted.