Datasheet summary
ULP2012 100
Engineering summary from PDF text extraction for ULP2012 100. Verify every value with the OEM datasheet.
Summary
Product identification
The ULP2012-100 is an Ultra Low Pressure (ULP Series) reverse osmosis membrane element.
Applications
This Vontron RO element is designed for treating low-salinity water sources, including:
- Tap water
- Well water
- Centralized water supply
- Underground water It is suitable for water purification devices in:
- Residences
- Hospitals
- Laboratories
Product water
The ULP2012-100 offers the following performance characteristics:
- Permeate Flow: 100 GPD (0.38 m³/d)
- Note: Each membrane element may have ±15% variation of permeate flow.
- Rejection Rate: 99%
- Note: Rejection Rate ±2%.
- Minimum Rejection: 97%
These performance figures are based on the following testing conditions:
- Testing Pressure: 60 psi (0.41 MPa)
- Temperature of Testing Solution: 25℃
- Concentration of Testing Solution (NaCl): 250 ppm
- pH of Testing Solution: 6.5~8.5
- Recovery of Single Element: 15%
Operating limits
The document states that operating limits and operational guidelines are part of the limitations for the three-year warranty. Users should refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation.
Preservation and First Use
- Preservation Solution:
- Dry membrane elements: No preservation solution upon leaving the factory. Must be maintained wet after soaking.
- Wet membrane elements: 1.0% sodium bisulfite (with 10% propylene glycol antifreeze added in winter) for storage, vacuum packaged. Preservation solution is needed if elements are not used for a long time.
- Initial Flushing (First Use):
- Flush for 15-25 minutes at low pressure (not suitable for soaking or soaking overnight).
- Then flush for 60-90 minutes at high pressure (the water flow should not be less than 50% of the system design water flow).
- The permeate and concentrated water produced during the first hour of initial operation must be discharged.
- Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
Mechanical / hydraulic
The product dimensions are as follows:
- A: 298 mm
- B: 48 mm
- C: 17 mm
- D1: 21 mm
- D2: 21 mm
Disclaimer Product performance may vary under different conditions. This information is for reference only and is not a guarantee of performance in actual applications. The user is responsible for determining product suitability and ensuring compliance with applicable laws and regulations. This extraction may not include all figures, footnotes, or the latest revisions; contractual data must match the OEM PDF revision used on the project.