ULP2812 300

Engineering summary from PDF text extraction for ULP2812 300. Verify every value with the OEM datasheet.

Summary

Product identification

The ULP2812-300 is an Ultra Low Pressure Membrane Element from the ULP Series, independently developed by VONTRON.

Application

This RO element is designed for the treatment of low-salinity water resources, including tap water and well water. It is suitable for water purifying devices in:

  • Residential settings
  • Hospitals
  • Laboratories
  • Centralized water supply systems
  • Underground water sources

Product Performance

This element operates under extra-low pressure conditions.

Testing Conditions:

  • Testing Pressure: 100 psi (0.69 MPa)
  • Temperature of Testing Solution: 25 ℃
  • Concentration of Testing Solution (NaCl): 250 ppm
  • pH of Testing Solution: 6.5~8.5
  • Recovery of Single Element: 15 %

Performance Data (ULP2812-300):

  • Permeate Flow: 300 GPD (1.13 m³/d)
  • Rejection Rate: 98.5 %
  • Min. Rejection: 96.5 %

Note: Each membrane element may have ±15% variation of permeate flow, and the Rejection Rate may vary by ±2%.

Mechanical / hydraulic

Dimensions of the membrane element:

  • A: 298 mm
  • B: 68 mm
  • C: 17 mm
  • D1: 21 mm
  • D2: 21 mm

Important Information

  • Preservation: Dry membrane elements do not contain preservation solution. Wet membrane elements use 1.0% sodium bisulfite (with 10% propylene glycol antifreeze added in winter) for storage, and are vacuum packaged.
  • Storage: Dry membrane elements must be kept wet after initial soaking. Wet membrane elements not in use for extended periods require preservation solution.
  • Initial Flushing: When first used, flush the element for 15-25 minutes at low pressure (avoid overnight soaking), then for 60-90 minutes at high pressure (water flow should be at least 50% of the system design flow).
  • Initial Discharge: The permeate water and concentrated water produced during the first hour of operation must be discharged.
  • Warranty: The operating limits and guidelines provided are part of the limitations for the three-year membrane element warranty.
  • Chemicals: The addition of any chemicals that could affect the membrane element during storage or operation is prohibited.
  • Further Details: For comprehensive instructions on installation, commissioning, storage, and transportation, refer to the Product Manual.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. For contractual data and complete product information, always refer to the specific OEM PDF revision used on the project.