Datasheet summary
ULP3013 600
Engineering summary from PDF text extraction for ULP3013 600. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: ULP3013-600
- Series: Ultra Low Pressure Membrane Elements (ULP Series)
- Application:
- Designed for treatment of low-salinity water resources such as tap water and well water.
- Applicable to water purifying devices for residence, hospital, and laboratory.
- Used to treat centralized water supply, underground water, and other water sources.
Product water
- Permeate Flow: 600 GPD (2.27 m³/d)
- Rejection Rate: 98 %
- Minimum Rejection: 96 %
- Test Conditions:
- Testing Pressure: 100 psi (0.69 MPa)
- Temperature of Testing Solution: 25℃
- Concentration of Testing Solution (NaCl): 250 ppm
- pH of Testing Solution: 6.5~8.5
- Recovery of Single Element: 50 %
- Performance Variation:
- Each membrane element may have ±15% variation of permeate flow.
- Rejection Rate ±2%.
Mechanical / hydraulic
Product Size
- A: 333 mm
- B: 67.8 mm
- C: 17 mm
- D1: 15 mm
- D2: 20 mm
Important Information
- Preservation:
- Dry membrane elements have no preservation solution upon leaving the factory.
- Wet membrane elements use 1.0% sodium bisulfite (with 10% propylene glycol antifreeze in winter) as preservation solution for storage treatment and are vacuum packaged.
- Storage:
- Dry membrane elements should always be maintained wet after soaking.
- When wet membrane elements are not used for a long time, preservation solution is needed to soak the elements.
- Initial Operation:
- When the membrane element is used for the first time, it is recommended to flush it for 15-25 minutes at low pressure (not suitable for soaking or soaking overnight), and then flush it for 60-90 minutes at high pressure (the water flow should not be less than 50% of the system design water flow).
- The permeate water and concentrated water within the first hour of the initial operation of the membrane element should all be discharged.
- Warranty: The operating limits and operational guidelines given in this technical information are part of the limitations of the three-year warranty on the membrane element.
- Chemical Use: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited. Vontron Technology will not be liable for any consequences arising from the use of such chemicals.
- Further Details: Please refer to the Product Manual for details on installation, commissioning, storage, and transportation of membrane elements.