Datasheet summary
ULP3113 800
Engineering summary from PDF text extraction for ULP3113 800. Verify every value with the OEM datasheet.
Summary
Product identification
The ULP3113-800 is an Ultra Low Pressure (ULP Series) reverse osmosis (RO) membrane element, developed by VONTRON.
Application
This membrane is designed for treating low-salinity water sources such as:
- Tap water
- Well water
- Underground water
- Centralized water supply
It is applicable for:
- Residential water purifiers
- Hospital water purification devices
- Laboratory water purification devices
Product performance
Performance is tested under specified conditions:
- Testing Pressure: 100 psi (0.69 MPa)
- Temperature of Testing Solution: 25℃
- Concentration of Testing Solution (NaCl): 250 ppm
- pH of Testing Solution: 6.5~8.5
- Recovery of Single Element: 50 %
| Model | Permeate Flow GPD (m³/d) | Rejection Rate (%) | Min. Rejection (%) |
|---|---|---|---|
| ULP3113-800 | 800 (3.02) | 98 | 96 |
Note:
- Each membrane element may have ±15% variation in permeate flow.
- Rejection Rate may vary by ±2%.
Mechanical / hydraulic
| Dimension | Value (mm) |
|---|---|
| A | 333 |
| B | 78 |
| C | 17 |
| D1 | 15 |
| D2 | 20 |
Important Information
- Preservation:
- Dry membrane elements leave the factory without preservation solution.
- Wet membrane elements contain 1.0% sodium bisulfite (and 10% propylene glycol antifreeze in winter) as a preservation solution, and are vacuum packaged.
- Storage:
- Dry membrane elements must always be kept wet after initial soaking.
- Wet membrane elements, when not in use for a long time, require a preservation solution soak.
- Initial Usage:
- It is recommended to flush the membrane element first at low pressure for 15-25 minutes.
- Follow with a high-pressure flush for 60-90 minutes (water flow should be no less than 50% of the system design flow).
- The permeate water and concentrated water produced within the first hour of initial operation must be discharged.
- Warranty: The operating limits and guidelines provided are part of the limitations for the three-year warranty on the membrane element.
- Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
- Documentation: Refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation.
Disclaimer: This summary is based on the extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used for the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.