VUF 2880
Engineering summary from PDF text extraction for VUF 2880. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: VUF-2880
- Series: VUF Series
- Type: Hollow Fiber UF Membrane Element
- Product Size: 1.0 inch (25.4 mm)
- Active Membrane Area: 75 m²
- System Flux: 30-120 LMH (L/h)
- MWCO: 150000 Da
- Membrane Material: PVDF
- Sealant: Epoxy Resins
Operating Limits
- Maximum Operating Pressure: 0.60 MPa
- Maximum Backwash Transmembrane Pressure (TMP): 0.25 MPa
- Maximum Filtration Transmembrane Pressure (TMP): 0.20 MPa
- Maximum Temperature: 45℃
- Allowed pH Range for Feedwater in Operation: 2-11
Feed Water
Hollow fiber UF membrane elements are primarily used for removing suspended solids, colloids, and bacteria from water solutions. The allowed pH range for operation is 2-11.
Applications
- Tap water purification
- Seawater desalination pre-treatment
- Wastewater reuse purification
Important Operational Information
- Regular maintenance of ultrafiltration membrane equipment, pumps, valves, and meters is crucial.
- Conduct regular inspections for abnormalities; monitor chemical tank levels and replenish as needed.
- Record parameters such as ultrafiltration membrane inlet pressure, concentrated water pressure, produced water pressure, produced water flow, and turbidity.
- Always keep the ultrafiltration membrane in a wet state; dehydration and drying will cause irreversible damage.
- Electrical operations must be performed by trained and certified personnel.
- On-site operations require appropriate working clothes and protective equipment for safety.
- In case of system failure, check the cause promptly. For minor faults like system leakage, perform overhaul in time. For emergency failures, contact the original manufacturer.