Back to Vontron Membranes
Vontron logo

Datasheet summary

VUF8040 10K 31F

Engineering summary from PDF text extraction for VUF8040 10K 31F. Verify every value with the OEM datasheet.

Summary

Product Identification

The VUF series offers spiral-wound ultrafiltration membrane elements, with the specific model VUF8040-10K/31F detailed. These elements are designed for the separation and concentration of materials with a Molecular Weight Cut-Off (MWCO) ranging from 4k to 67k Da.

The VUF series is primarily used for:

  • Screening and separation of organic substances in industries such as food processing and bioengineering.

The elements feature a feed channel spacer thickness of 31, 46, or 90 mil, and are compatible with fiberglass or sanitary-grade housings.

Product Performance

Model: VUF8040-10K/31F

  • MWCO: 10000 Da
  • Permeate Flow: 7000 GPD (26.5 m³/d)
  • Active Membrane Area: 400 ft² (37.2 m²)
  • Feed Spacer Thickness: 31 mil

Note: Performance data is based on a 1000 mg/L PEG10000 solution at 40 psi (0.28 MPa) operating pressure, 25℃ temperature, and 15% recovery rate. Each membrane element may exhibit ±25% variation in permeate flow.

Operating Limits

  • Maximum operating pressure: 300 psi (2.07 MPa)
  • Maximum feedwater temperature: 40 ℃
  • Maximum inlet flow rate: 19 m³/h
  • Maximum concentration of free chlorine: Not specified
  • Maximum pressure drop per element: 15 psi (0.1 MPa)
  • Allowed pH range for feedwater in operation: 3-10
  • Allowed pH range for chemical cleaning: 2-12
  • Maximum feedwater flow SDI₁₅: 5

Mechanical / Hydraulic

  • Packing carton (L:W:H): 1080×216×232 mm
  • Connector material number: 3.02.09.0006

Important Information

  • Preservation:
    • Dry membrane elements leave the factory without preservation solution but must be kept wet after soaking.
    • Wet membrane elements are vacuum packaged with 1.0% sodium bisulfite as a preservation solution (10% propylene glycol antifreeze is added in winter). Preservation solution is required for wet elements not in use for extended periods.
  • Initial Operation:
    • Recommended flushing for 15-25 minutes at low pressure (avoid soaking overnight).
    • Follow with 60-90 minutes flushing at high pressure (water flow not less than 50% of system design).
    • Permeate water and concentrated water from the first hour of initial operation must be discharged.
  • General Use:
    • Operating limits and guidelines are part of the three-year warranty.
    • Addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
    • Refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation.

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions found in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.