Product identification

  • Model: VUF8040-4K/31F
  • Series: VUF series Spiral Wound Ultrafiltration Membrane Elements
  • Application: Primarily for separation and concentration of specific materials with a Molecular Weight Cut Off (MWCO) at 4k, 6k, 8k, 10k, 20k, 67k Da. This includes screening and separation of organic substances in industries such as food processing and bioengineering.
  • Feed Channel Spacer Options: 31, 46, and 90 mil.
  • Housing: Favorable with fiberglass housing or sanitary-grade housing.

Product Performance

  • Model: VUF8040-4K/31F
  • MWCO: 4000 Da
  • Permeate Flow: 8700 GPD (32.9 m³/d)
  • Active Membrane Area: 400 ft² (37.2 m²)
  • Feed Spacer Thickness: 31 mil

Test Conditions for Performance:

  • 1000 mg/L solution PEG4000
  • Operating pressure 60 psi (0.41 MPa)
  • Temperature at 25℃
  • Recovery rate at 15%

Note: Each membrane element may have ±20% variation of permeate flow.

Operating Limits

  • Maximum operating pressure: 300 psi (2.07 MPa)
  • Maximum feedwater temperature: 40 ℃
  • Maximum inlet flow rate: 19 m³/h
  • Maximum pressure drop per element: 15 psi (0.1 MPa)
  • Allowed pH range for feedwater in operation: 3-10
  • Allowed pH range for chemical cleaning: 2-12
  • Maximum feedwater flow SDI₁₅: 5

Mechanical / Hydraulic

  • Packing carton (L:W:H): 1080×216×232mm
  • Connector material number: 3.02.09.0006

Important Information

  • Preservation:
    • Dry membrane elements are shipped without preservation solution and vacuum packaged. They must be kept wet after soaking.
    • Wet membrane elements are shipped with 1.0% sodium bisulfite (with 10% propylene glycol antifreeze added in winter) as a preservation solution and are vacuum packaged. If not used for a long time, elements require soaking in preservation solution.
  • Initial Operation:
    • Recommended to flush for 15-25 minutes at low pressure (not suitable for soaking or soaking overnight).
    • Follow with a 60-90 minute flush at high pressure (water flow should not be less than 50% of the system design flow).
    • Permeate and concentrated water produced during the first hour of initial operation must be discharged.
  • Warranty: The operating limits and guidelines provided are part of the limitations of the three-year warranty on the membrane element.
  • Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
  • Documentation: Refer to the Product Manual for detailed instructions on installation, commissioning, storage, and transportation.