VUF8040 67K 31F

Engineering summary from PDF text extraction for VUF8040 67K 31F. Verify every value with the OEM datasheet.

Summary

Product Identification

The VUF series consists of Spiral Wound Ultrafiltration Membrane Elements.

This series is mainly used for separation and concentration of specific material with molecular weight cut off (MWCO) at 4k, 6k, 8k, 10k, 20k, 67k Da. VUF series applies feed channel spacers of 31, 46 and 90mil, and can be equipped with fiberglass housing or sanitary-grade housing.

Applications include:

  • Screening and separation of organic substances
  • Food processing
  • Bioengineering and other industries

Product Performance

ModelMWCO (Da)Permeate Flow (GPD)Permeate Flow (m³/d)Active Membrane Area (ft²)Active Membrane Area (m²)Feed Spacer Thickness (mil)
VUF8040-67K/31F670002500094.640037.231

Performance measured under the following conditions:

  • 300 mg/L Bovine Serum Albumin solution
  • Operating pressure 40 psi (0.28 MPa)
  • Temperature at 25 ℃
  • Recovery rate at 15%
  • Each membrane element may have ±25% variation of permeate flow.

Operating Limits

  • Maximum operating pressure: 300 psi (2.07 MPa)
  • Maximum feedwater temperature: 40 ℃
  • Maximum pressure drop per element: 15 psi (0.1 MPa)

Feed Water

  • Allowed pH range for feedwater in operation: 3-10
  • Allowed pH range for chemical cleaning: 2-12
  • Maximum feedwater SDI₁₅: 5
  • Maximum inlet flow rate: 19 m³/h
  • Maximum concentration of free chlorine: Not specified

Mechanical / Hydraulic

  • Packing carton (L:W:H): 1080×216×232 mm
  • Connector material number: 3.02.09.0006

General Operational Notes

  • Preservation: Dry membrane elements have no preservation solution. Wet membrane elements contain 1.0% sodium bisulfite (with 10% propylene glycol antifreeze in winter) for storage and are vacuum packaged.
  • Storage: Dry membrane elements should always be maintained wet after soaking. Wet membrane elements not used for a long time require preservation solution.
  • Initial Start-up:
    • Flush for 15-25 minutes at low pressure (not suitable for soaking or soaking overnight).
    • Then flush for 60-90 minutes at high pressure (water flow should not be less than 50% of system design flow).
    • Permeate and concentrated water from the first hour of operation must be discharged.
  • Chemicals: The addition of any chemicals that may affect the membrane element during storage and operation is prohibited.
  • Refer to the Product Manual for detailed information on installation, commissioning, storage, and transportation.

Disclaimer: Product performance may vary under different conditions. The information in this document is for reference only and should not be relied upon as a guarantee of performance in actual applications. The user is responsible for determining suitability and ensuring compliance with applicable laws and regulations. The operating limits and operational guidelines given here are part of the limitations of the three-year warranty. Technical progress and product replacement may lead to changes in product information without prior notice. This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.