Datasheet summary
ABK series
Engineering summary from PDF text extraction for ABK series. Verify every value with the OEM datasheet.
Summary
Product identification
ABK filters are pre-filtration strainers featuring a reusable stainless steel basket, designed for long service life.
Features
- Stainless steel housing and basket
- Reusable baskets
- No mechanical moving parts
- Easy to install, maintain, and clean basket
Operating Limits
- Max working pressure: 10 bar (145 psi)
- Max working temperature: 80 °C (140 °F)
Note: Flow rates are referenced to a 100 µm filtrating mesh, water temperature of 20 °C, and turbidity (NTU) < 1.
Mechanical / Hydraulic
ABK filters can support flow rates up to 600 m³/h (2642 US gpm). They are available with five sizes of screens, covering a filtration range of 100 µm to 5000 µm. Inlet/outlet flanged connections are available between 2″ and 10″.
Filter Specifications
- Filter sizes: 16, 23, 35, 55, 81
- Screen Area:
- 1600 cm² (248 in²)
- 2300 cm² (357 in²)
- 3500 cm² (543 in²)
- 5500 cm² (853 in²)
- 8100 cm² (853 in²)
- Filtration degrees: 5000 / 2000 / 1000 / 500 / 200 / 100 µm
- Screen types: Basket: Perforated sheet or Multi-layers in Stainless Steel AISI 316
Materials of Construction
- Filter Body: AISI 304 / AISI 316 / SAF 2205 / 254 SMO
- Cover: AISI 304 / AISI 316 / SAF 2205 / 254 SMO
- Screen support: AISI 316 / SAF 2205
- Gasket: EPDM
Standard Equipment
ABK filters are supplied with:
- Supporting legs
- Manual drain valve
- Manual vent valve
- Pressure gauges
Optional Accessories
ABK filters can be equipped with a magnetic kit to capture particulate metal present in the water.
Head Loss
Head loss data is available, referred to filters with a 100 µm filtrating mesh and clean water. See the official PDF for exact tabulated values.
Dimensions and Weights
Dimensions are for "Shape Z" models. Drain connection for all models is 1" thrdF.
| Filter Model | In/Out Conn. | Filter Area [cm²] | Max Flow rate [m³/h] | A [mm] | B [mm] | C [mm] | D [mm] | E [mm] | F [mm] | G [mm] | X [mm] | Weight [Kg] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABK 16Z2 | 2" flg | 1600 | 30 | 405 | 206 | 950 | 1050 | 700 | 800 | 450 | 550 | 37 |
| ABK 16Z3 | 3" flg | 1600 | 60 | 405 | 206 | 950 | 1050 | 700 | 800 | 450 | 550 | 38 |
| ABK 16Z4 | 4" flg | 1600 | 100 | 405 | 206 | 950 | 1050 | 700 | 800 | 450 | 550 | 39 |
| ABK 23Z3 | 3" flg | 2300 | 60 | 405 | 206 | 1150 | 1250 | 900 | 1000 | 500 | 600 | 42 |
| ABK 23Z4 | 4" flg | 2300 | 100 | 405 | 206 | 1150 | 1250 | 900 | 1000 | 500 | 600 | 45 |
| ABK 23Z6 | 6" flg | 2300 | 180 | 405 | 206 | 1150 | 1250 | 900 | 1000 | 500 | 600 | 48 |
| ABK 35Z4 | 4" flg | 3500 | 100 | 475 | 273 | 1200 | 1300 | 950 | 1050 | 650 | 750 | 47 |
| ABK 35Z6 | 6" flg | 3500 | 220 | 475 | 273 | 1200 | 1300 | 950 | 1050 | 650 | 750 | 50 |
| ABK 35Z8 | 8" flg | 3500 | 270 | 475 | 273 | 1200 | 1300 | 950 | 1050 | 650 | 750 | 55 |
| ABK 55Z4 | 4" flg | 5500 | 100 | 475 | 273 | 1500 | 1600 | 1250 | 1350 | 950 | 1050 | 55 |
| ABK 55Z6 | 6" flg | 5500 | 220 | 475 | 273 | 1500 | 1600 | 1250 | 1350 | 950 | 1050 | 60 |
| ABK 55Z8 | 8" flg | 5500 | 390 | 475 | 273 | 1500 | 1600 | 1250 | 1350 | 950 | 1050 | 65 |
| ABK 81Z6 | 6" flg | 8100 | 220 | 650 | 406 | 1700 | 1300 | 650 | 450 | 150 | 900 | 95 |
| ABK 81Z8 | 8" flg | 8100 | 390 | 650 | 406 | 1700 | 1300 | 650 | 450 | 150 | 900 | 100 |
| ABK 81Z10 | 10" flg | 8100 | 600 | 650 | 406 | 1700 | 1300 | 650 | 450 | 150 | 900 | 105 |
Note: The specific meanings of dimensions A, B, C, D, E, F, G, and X are not detailed in the provided text. Refer to the official PDF for corresponding diagrams.
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)