Summary

Product Identification

The ABV series filters are automatic self-cleaning filters featuring a double cleaning system. They utilize a combined action of brushes and vacuum pads, making them particularly suitable for river water and handling coarse suspended solids.

General Features

  • Double Cleaning System: Combines brushes for coarse solids and vacuum pads for finer solids.
  • Multi-layers screens: Available with various filtration degrees.
  • Continuous Flow: No interruption during the cleaning cycle.
  • Robust and Economic: Designed for automated filtration.
  • Simple and Reliable: Cleaning mechanism with special pads and brushes.

Operating Limits

  • Min working pressure: 2 bar (29 psi) (during cleaning cycle)
  • Max working pressure: 10 bar (145 psi)
  • Max working temperature: 60 °C (140 °F)

Feed Water

  • Flow rates are referred to 100 µm filter screen, water with NTU < 1 and temperature of 20 °C.

Filtration Screens

  • Screen Area: Available up to 11,000 cm² (1705 in²) across different filter sizes.
    • Smallest filter size: 1,600 cm² (248 in²)
    • Largest filter size: 11,000 cm² (1705 in²)
  • Filtration Degrees: 1000 / 800 / 500 / 400 / 200 / 100 / 50 / 25 / 10 µm
  • Screen Types:
    • Stainless Steel AISI 316
    • Multi-layers SS AISI 316 + PETP (Polyester)

Cleaning Cycle

  • Cleaning Device: Flexible Suction PADS (PVC material) with BRUSH.
  • Cleaning Cycle Time:
    • 12 sec for Filter sizes 16, 23
    • 24 sec for Filter sizes 35, 55
    • 40 sec for Filter size 72
    • 30 sec for Filter sizes 81, 110
  • Min Cleaning Flow Rate:
    • 6 m³/h (26 US gpm) for Filter size 16
    • 9 m³/h (39 US gpm) for Filter size 23
    • 15 m³/h (66 US gpm) for Filter sizes 35, 55
    • 30 m³/h (132 US gpm) for Filter sizes 72, 110
    • 20 m³/h (88 US gpm) for Filter size 81
  • Drained Water for Cleaning:
    • 35 L (Filter size 16)
    • 40 L (Filter size 23)
    • 110 L (Filter size 35)
    • 130 L (Filter size 55)
    • 290 L (Filter size 72)
    • 180 L (Filter size 81)
    • 220 L (Filter size 110)
  • Drain Valve:
    • 2 x 1"½ flanged EN 1092-1 (Filter sizes 16, 23)
    • 1 x 1"½ + 1 x 2" flanged EN 1092-1 (Filter sizes 35, 55)
    • 2 x 2" flanged EN 1092-1 (Filter sizes 72, 81, 110)
  • Cleaning Criteria: Differential pressure (0.6 bar), time intervals, and manual operation.

Electrical

  • Standard Controller: AWC Basic controller (differential pressure and/or preset time and/or manual start, IP56, 4DI, 2AI, 4DO, Graphic Display 1x24 digit).
  • Available Controllers: AWC FULL controller, AWP FULL controller.
  • Supply Voltage:
    • 230 Vac 1-phase 50/60 Hz
    • Optional: 400 Vac 3-phases 50/60 Hz
  • Control Voltage: 24 Vdc
  • Electric Motor Power:
    • 110 W (Filter sizes 16, 23, 35, 55)
    • 210 W (Filter sizes 72, 81, 110)
  • Electric Motor Consumption: 2.8 A (all models)

Mechanical / Hydraulic

  • Inlet/Outlet Connections: Flanged EN 1092-1, ranging from 2" up to 12" depending on the model. (Note: Specific models like ABV 198H16 have 16" connections which is beyond the 12" general range specified in the prose description, but appears in the detailed tables).
  • Max Flow Rate: Up to 800 m³/h (3522 US gpm). Individual model flow rates vary from 30 m³/h to 1400 m³/h for the ABV 198H16/L16 models (which are not explicitly listed in the technical data general section). See the official PDF for exact tabulated values for each model.
  • Materials:
    • Filter Body: AISI 304 / AISI 316 / SAF 2205 / 254 SMO
    • Cover: AISI 304 / AISI 316 / SAF 2205 / 254 SMO
    • Screen Support: AISI 316 / SAF 2205
    • Gasket: EPDM - NBR
  • Dimensions and Weight: Filters are available in "Shape H" and "Shape L" configurations. Detailed dimensions (A, B, C, D, E, X, Y in mm) and weights (Kg) vary significantly by model and shape. See the official PDF for exact tabulated values for each model, including specific In/Out and Drain connections, Filter Area, and Max Flow Rate.

Head Loss

Head loss data refers to a filtrating screen of 100 µm, water with NTU < 1, and a temperature of 20 °C. See the official PDF for head loss graphs.