AVC in GRP Filter

Engineering summary from PDF text extraction for AVC in GRP Filter. Verify every value with the OEM datasheet.

Summary

Product identification

The AVC filters are automatic self-cleaning filters designed for high efficiency, continuous filtration, and low cleaning water consumption. They feature a suction scanning self-cleaning mechanism driven by an electric motor.

Key features:

  • Multi-layers screens with several filtration degrees
  • No interruption of flow during the cleaning cycle
  • Minimum cleaning water consumption
  • Very reliable and efficient cleaning mechanism with suction scanner

Standard controller:

  • AWC Basic controller (differential pressure and/or preset time and/or manual start, IP56, 4DI, 2AI, 4DO, Graphic Display 1x24 digit) Available controllers:
  • AWC FULL controller
  • AWP FULL controller

Operating limits

  • Max flow rate: 220 m³/h (969 US gpm) - referred to 100 µm filter screen, water with NTU < 1, and temperature of 20 °C
  • Min working pressure: 2 bar (29 psi) - during cleaning cycle
  • Max working pressure: 10 bar (145 psi)
  • Max working temperature: 60 °C (140 °F)

Feed water

  • The specified flow rates and head loss are referred to water with NTU < 1 and a temperature of 20 °C.

Mechanical / hydraulic

  • Filter size: 72
  • Inlet/outlet diameter: 6" flanged EN 1092-1
  • Screen area: 7,200 cm² (1116 in²)
  • Filtration degrees: 1000 / 800 / 500 / 400 / 200 / 100 / 50 / 25 / 10 µm
  • Screen types: Screens: Stainless Steel AISI 316 or Multi-layers SS AISI316 + PETP (Polyester)
  • Cleaning device: Flexible Suction PADS - PVC material
  • Cleaning cycle time: 20 sec
  • Min cleaning flow rate: 30 m³/h (132 US gpm)
  • Drained water for cleaning: 160 L
  • Drain valve: 2" flanged EN 1092-1
  • Cleaning criteria: Differential pressure (0.6 bar), time intervals, and manual operation

Materials

  • Filter Body: GRP
  • Cover: GRP
  • Screen support: SAF 2205
  • Gasket: EPDM - NBR

Head Loss

Head loss data is not provided in the text. Head loss values are stated to be referred to a filtrating screen of 100 µm, water with NTU < 1, and a temperature of 20 °C. See the official PDF for exact tabulated values.

Electrical

  • Supply voltage: 230 Vac 1-phase 50/60 Hz
  • Optional supply voltage: 400 Vac 3-phases 50/60 Hz
  • Control voltage: 24 Vdc
  • Electric motor power: 110 W
  • Electric motor consumption: 2.8 A

Dimensions

Specific dimensions for the AVC 72H6 model are provided:

Filter ModelIn/Out Conn.Drain Conn.Filter Area [cm²]Max Flow rate [m³/h]A [mm]B [mm]C [mm]D [mm]E [mm]X [mm]Y [mm]Weight [Kg]
AVC 72H66" flg2" flg720022018165531050300270120030075