Back to Axeon Filtration
Axeon logo

Datasheet summary

General Cataloque

Engineering summary from PDF text extraction for General Cataloque. Verify every value with the OEM datasheet.

Summary

Product Identification

AXEON Water Technologies provides membrane technology-based products, including membrane systems, elements, housings, and chemicals, for industrial, commercial, and residential applications. All AXEON residential membranes are NSF 58 listed and approved.

Key product series mentioned include:

  • AXEON HF5-Series Membrane Elements
  • AXEON PVC Membrane Housings
  • AXEON HF1-Series Membranes (Low Energy RO)
  • AXEON HF4-Series Membranes (Extra Low Energy RO)
  • AXEON HF5-Series Membranes (Ultra Low Energy RO)
  • AXEON HR3-Series Membranes (High Rejection RO)
  • AXEON NF3-Series Nanofiltration Membranes
  • AXEON NF4-Series Nanofiltration Membranes
  • AXEON TF-Series Residential Reverse Osmosis Polyamide-Thin Film Composite Membranes
  • AXEON Stainless Steel (SS) Membrane Housings

Membrane elements are shipped dry for indefinite shelf life and easier handling, with options for individually wet-tested elements. Elements are vacuum integrity tested.

Operating Limits

Membrane Elements (General for Commercial/Residential TF-Series)

  • Membrane Type: Polyamide Thin-Film Composite (for commercial and TF-Series residential)
  • Maximum Operating Temperature: 113°F (45°C)
    • Maximum temperature for continuous operations above pH10 is 95°F (35°C)
  • pH Range, Continuous Operation: 2 – 11
  • pH Range, Short Term Cleaning (30 Min.):
    • TF-Series Residential: Not specified, but implied to be similar to others.
    • HF1, HF4, HF5, HR3 Series: 1 – 13
    • NF3, NF4 Series: 1 – 12
  • Maximum Feed Silt Density Index (SDI): 5
  • Chlorine Tolerance: 0 ppm (free chlorine and other oxidizing agents will cause premature membrane failure)

Membrane Housings (PVC)

  • Maximum Operating Pressure: 225 psi @ 73°F (22°C)
  • Maximum Operating Temperature: 110°F (43°C)
  • Minimum Operating Temperature: 35°F (1°C)

Membrane Housings (Stainless Steel)

  • Maximum Operating Pressure: 250 psi / 17 bar
  • Maximum Operating Temperature: 120°F / 48°C
  • Minimum Operating Temperature: 35°F / 1°C

Feed Water

Test Parameters for Membrane Element Product Specifications:

  • TDS Filtered: 550 (5 Micron)
  • Type: De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

TF-Series Residential Membranes

  • Nominal Salt Rejection: 98.0% (for all listed TF-1812 models)
  • Minimum Salt Rejection: 96%
  • Maximum Pressure Drop: 10 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (lph)
200357TF-1812-2550 (3.44)25 (3.94)
200358TF–1812–3550 (3.44)35 (5.52)
200359TF–1812–5050 (3.44)50 (7.88)
200360TF–1812–7550 (3.44)75 (11.83)
200361TF–1812–10060 (4.13)100 (15.77)
300362TF–1812–15065 (4.48)150 (23.66)

HF1-Series Commercial Membranes (Low Energy RO)

  • Nominal Salt Rejection: 99.0%
  • Minimum Salt Rejection: 96%
  • Maximum Pressure Drop: 15 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (m³/d)
200374HF1 – 2514150 (10.34)225 (0.85)
200375HF1 – 2521150 (10.34)400 (1.51)
200376HF1 – 2540150 (10.34)1000 (3.79)
200377HF1 – 4014150 (10.34)600 (2.27)
200378HF1 – 4021150 (10.34)1000 (3.79)
200379HF1 – 4040150 (10.34)2500 (9.46)

HF4-Series Commercial Membranes (Extra Low Energy RO)

  • Nominal Salt Rejection: 99.0%
  • Minimum Salt Rejection: 96%
  • Maximum Pressure Drop: 13 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (m³/d)
200386HF4 – 2514100 (6.89)225 (0.85)
200387HF4 – 2521100 (6.89)400 (1.51)
200388HF4 – 2540100 (6.89)850 (3.22)
200389HF4 – 4014100 (6.89)600 (2.27)
200390HF4 – 4021100 (6.89)1000 (3.79)
200391HF4 – 4040100 (6.89)2500 (9.46)

HF5-Series Commercial Membranes (Ultra Low Energy RO)

  • Nominal Salt Rejection: 98.5%
  • Minimum Salt Rejection: 96%
  • Maximum Pressure Drop: 13 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (m³/d) (at 80 psi)Applied Pressure psi (bar)Permeate Flow Rate gpd (m³/d) (at 100 psi)
200392HF5 – 401480 (5.52)600 (2.27)100 (6.89)720 (3.72)
200393HF5 – 402180 (5.52)1000 (3.79)100 (6.89)1200 (4.54)
200394HF5 – 404080 (5.52)2500 (9.46)100 (6.89)3000 (11.36)

HR3-Series Commercial Membranes (High Rejection RO)

  • Nominal Salt Rejection: 99.5%
  • Minimum Salt Rejection: 96%
  • Maximum Pressure Drop: 13 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (m³/d)
200368HR3 – 2514225 (15.51)150 (0.57)
200369HR3 – 2521225 (15.51)250 (0.95)
200370HR3 – 2540225 (15.51)650 (2.46)
200371HR3 – 4014225 (15.51)400 (1.51)
200372HR3 – 4021225 (15.51)900 (3.41)
200373HR3 – 4040225 (15.51)2200 (8.33)

NF3-Series Commercial Membranes (Nanofiltration)

  • Nominal Salt Rejection: 40% – 50%
  • Minimum Salt Rejection: 96% (Appears to be a general statement, possibly less specific for NF)
  • Maximum Pressure Drop: 13 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (m³/d)
200401NF3 – 251470 (4.83)200 (0.76)
200402NF3 – 252170 (4.83)350 (1.33)
200403NF3 – 254070 (4.83)850 (3.22)
200404NF3 – 401470 (4.83)400 (1.51)
200405NF3 – 402170 (4.83)1000 (3.79)
200406NF3 – 404070 (4.83)2500 (9.46)

NF4-Series Commercial Membranes (Nanofiltration)

  • Nominal Salt Rejection: 80% – 90%
  • Minimum Salt Rejection: 96% (Appears to be a general statement, possibly less specific for NF)
  • Maximum Pressure Drop: 13 psi
  • Permeate flow for individual elements may vary +/- 20%.
Part NumberDescriptionApplied Pressure psi (bar)Permeate Flow Rate gpd (m³/d)
200407NF4 – 251470 (4.83)200 (0.76)
200408NF4 – 252170 (4.83)250 (0.95)
200409NF4 – 254070 (4.83)680 (2.57)
200410NF4 – 401470 (4.83)400 (1.51)
200411NF4 – 402170 (4.83)950 (3.60)
200412NF4 – 404070 (4.83)2000 (7.6)

Mechanical / Hydraulic

Membrane Elements

  • TF-Series Residential (1812 size):
    • Dimensions (inch (mm)): A=11.74 (298.2), B=10.00 (254), C=.86 (21.84), D=.88 (22.35), E=1.77 (45.08)
    • Designed to fit a standard 2” x 12” residential membrane housing.
  • Commercial Membranes (HF1, HF4, HR3, NF3, NF4 Series):
    • Feature a protective ABS shell.
    • Dimensions (A, B, C, D in inch (mm)):
      • 2.5-inch diameter elements (HF1, HF4, HR3, NF3, NF4 - 2514, 2521, 2540):
        • A (Length): 14 (355.6), 21 (533.4), 40 (1016.0)
        • B: 1.1 (27.94)
        • C: 0.75 (19.05)
        • D (Diameter): 2.4 (60.96)
      • 4-inch diameter elements (HF1, HF4, HR3, NF3, NF4 - 4014, 4021, 4040):
        • A (Length): 14 (355.6), 21 (533.4), 40 (1016.0)
        • B: 1.1 (27.94)
        • C: 0.75 (19.05)
        • D (Diameter): 3.95 (100.3)
  • HF5-Series Commercial Membranes:
    • Available in all standard 4-inch commercial sizes.
    • Feature a protective tape wound exterior.
    • Dimensions (A, B, C, D in inch (mm)):
      • 4-inch diameter elements (HF5 - 4014, 4021, 4040):
        • A (Length): 14 (355.6), 21 (533.4), 40 (1016.0)
        • B: 1.1 (27.94)
        • C: 0.75 (19.05)
        • D (Diameter): 3.95 (100.3)

PVC Membrane Housings

  • Materials: NSF Approved PVC, NSF Approved GTX® Material, NSF Approved EPR O-Rings.
  • Features: Side port entry, locking wedge, snap ring, removable end cap, double o-ring permeate seals.
  • Accommodate female flush cut elements. Quadra Port (4 open ports) housings available.
  • Approximate Dimensions (inches) and Connections (FNPT):
Part NumberDescriptionNumber of MembranesABCD Permeate Port SizeE Concentrate Port Size
200518AXEON 2514117143 3/4”3/8” FNPT3/8” FNPT
200519AXEON 2521124213 3/4”3/8” FNPT3/8” FNPT
200520AXEON 2540143403 3/4”3/8” FNPT3/8” FNPT
200521AXEON 40141191461/2” FNPT1/2” FNPT
200524AXEON 40211262161/2” FNPT1/2” FNPT
200527AXEON 40401454061/2” FNPT1/2” FNPT
200540AXEON 40802858063/4” FNPT1/2” FNPT
200552AXEON 40120312512063/4” FNPT1/2” FNPT

Note: The PVC housing table lists 'D' and 'E' as Permeate Port Size and Concentrate Port Size respectively, but the feed port size is not explicitly listed in this table header, though mentioned in earlier overview table as 3/8" or 1/2" FNPT matching concentrate/permeate for 2500/4000 series.

Stainless Steel (SS) Membrane Housings

  • Materials of Construction:
    • End Plug: Nylon
    • Clamp: 304 SS
    • End Plug Screws: 304 SS
    • O-Ring: Buna-N
    • Housing Body: 304L SS (1.80 mm thick)
  • Features: True-Clamp™ Integrated Clamping System, end entry connections, seamless housing body.
  • Accommodate any make of 2.5-inch or 4-inch nominal diameter spiral wound elements with a 3⁄4” diameter male product tube.
Part NumberDescriptionNumber of MembranesDiameterLengthFeed (FNPT)Permeate (FNPT)Concentrate (FNPT)
2029192514 SS-250E12.5”14”3/8”3/8”3/8”
2029202521 SS-250E12.5”21”3/8”3/8”3/8”
2029212540 SS-250E12.5”40”3/8”3/8”3/8”
2029224021 SS-250E14.0”21”1⁄2”1⁄2”1⁄2”
2029234040 SS-250E14.0”40”1⁄2”1⁄2”1⁄2”
2029244040 SS-250E14.0”40”3⁄4”1⁄2”3⁄4”

Disclaimer

This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual purposes, please refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.