Summary

Product Identification

Eaton offers a range of permanent media automatic self-cleaning filters and strainers, including:

  • 2596 Series: Pipeline strainers (F-Series, AFC/AFR, DCF, MCF, MCS are also listed as types)
  • F-Series: Tubular backwashing filters
  • AFC-Series: Tubular backwashing filters
  • AFR-Series: Tubular backwashing filters
  • DCF-Series: Pneumatically driven disc cleaning filters (models 400, 800, 1600, 3000)
  • MCF: Magnetically-coupled filter system
  • MCS-500 & MCS-1500: Magnetically-coupled strainers

Mechanical / Hydraulic

Model 2596 Series

  • Sizes:
    • 2"–8" (DN50–DN200) cast iron or stainless
    • 2"–48" (DN50–DN1200) fabricated (Available in 2", 3", 4", 4L", 6", 8", 10", 12", 14", 16", 20", 24", 30", 36" and 48" sizes)
    • 10"–16" (DN250–DN400) cast ductile iron
  • Flow rates:
    • Up to 7,950 m³/h (for larger fabricated units)
    • Up to 400 m³/h (for 2"-8" sizes)
    • Up to 1,475 m³/h (for 10"-16" sizes)
  • Construction: Fabricated carbon steel, various grades of stainless steel (duplex or super-duplex), MONEL®, cast iron, or cast ductile iron.
  • Connections: Flanged, screwed, or socket weld.
  • Screen options: Convoluted element screen or DuraWedge® element (V-shaped profile wire). Retention ratings from 380 microns to 3/16" openings are available.

F-Series Tubular Backwashing Filter

  • Flow rates: Up to 680 m³/h
  • Solids removal: From 2 to 1,700 µm

AFC-Series Tubular Backwashing Filter

  • Flow rates: Up to 680 m³/h
  • Solids removal: From 2 to 1,700 microns
  • Configuration: Systems available in single, duo, and multiplex configurations.

AFR-Series Tubular Backwashing Filter

  • Flow rates: Up to 450 m³/h
  • Solids removal: From 2 to 1,700 microns
  • Footprint: Compact one-square-meter.
  • Configuration: Configured with an array of up to eight 4" (101.8 mm) or 6" (152.4 mm) body tubes surrounding a central cleaning valve.

DCF-Series Disc Cleaning Filter

  • Screens: Stainless steel screens from 15 micron slots to 1/4" perforations.
  • Cleaning Discs: UHMWPE, Urethane, Teflon, or Kynar®.
  • DCF-3000 Flow Rates:
    • Up to 110 m³/h for highly viscous, abrasive, or sticky liquids.
    • Up to 340 m³/h for water-like liquids.

MCF Magnetically-Coupled Filter

  • Throughput: Up to 40 m³/h.
  • Design: Simplified design with only 25 total parts.
  • Element Ratings: 15 to 1,600 microns (slotted wedgewire). Perforated or wire mesh elements available for special applications with 1.6, 3.2, and 6.35 mm pore size.

MCS-500 & 1500 Magnetically-Coupled Strainers

  • MCS-500 Flow Rate: Up to 110 m³/h.
  • MCS-1500 Flow Rate: Up to 340 m³/h.

Filter and Strainer Elements

  • Tubular Backwash Filters:
    • Wire mesh or fabric over a stainless steel backing.
    • High-strength slotted wedge-wire element.
    • AccuFlux® media elements featuring ultra-high surface area, clustered element designs (7 or 15 individual, replaceable filter tubes).
    • Economical TRI-CLUSTER® design features three 38.1 mm diameter tubes for 40% greater surface area than single element designs.
    • Ratings from 2 to 1,650 microns are available.
  • Disc Cleaned Models (DCF, MCF, MCS):
    • Slotted wedgewire design.
    • Ratings of 15 to 1,600 microns are available.
    • Perforated or wire mesh elements available for special applications. Elements are available with 1.6, 3.2, and 6.35 mm pore size.

Operating Limits

  • AFC-Series: High-pressure operation up to 69 bar (1000 psi).

General Features

  • Automatic backwashing for operator-free service and minimal backwash effluent (<2% of system volume for F, AFC, AFR Series).
  • Exclusive idL Seal for leak-free service (available up to 30" for 2596 Series).
  • Unitized/modular assembly for easy maintenance.
  • Compact design.
  • Eliminates the need for disposable media, reducing disposal costs, labor, and inventory.
  • Reduction in product loss and a more thorough contaminant purge.
  • Virtually maintenance-free with near 100% uptime.
  • Smooth pipe and nozzle connection transitions to avoid dead spots and minimize pressure drop (F, AFC, AFR Series).
  • Isolated top-to-bottom backwash for complete and efficient media cleaning (F, AFR Series).
  • 3-way valves on multiplex filters allow fast, frequent sequencing and maximum backwashing cleaning force (F, AFC Series).
  • Cenpeller™ technology improves circular flow, forcing debris against the element surface for easier and more efficient backwashing (2596 Series).
  • Magnetically coupled actuation eliminates dynamic seals (MCF, MCS).
  • Easy in-line installation (MCS).
  • Continuous 24/7 operation (MCS, MCF even during cleaning cycles).
  • Easy no-tools access for routine maintenance and service (MCF - 5 minutes only!).
  • Various modifications (ETO) possible on request.
  • Design Codes:
    • AD2000
    • CE stamp acc. PED is available
    • EN13445 or ASME Section VIII Div. 1 code stamp available on request