Product identification

The GFHNY-Series High Purity Food and Beverage Grade Nylon and Plus+ Nylon Filter Cartridges feature a nylon 6,6 membrane, designed for superior microbial retention in highly stable consumables. The optional positive zeta potential surface charge (Plus+) enhances retention for particulates smaller than the stated micron rating, assisting in the removal of haze, color bodies, and endotoxins.

Cartridges are manufactured in a clean room environment and flushed with 18 megaohm ultra-high purity water to achieve cleanliness and low extractables. They are designed to tolerate repeated hot water sanitization and in situ steam sterilization cycles for maximum service life. Each element is diffusion tested for integrity to assure optimal performance.

Typical Applications

  • Bottled Water
  • Wine
  • Soft Drinks
  • Pharmaceutical
  • Fermentation
  • Endotoxin Removal

Mechanical / Hydraulic

  • Dimensions
    • Length: 10 to 40 inches (25.4 to 101.6 cm) nominal
    • Outside Diameter: 2.70 inches (7.0 cm) nominal
  • Construction Materials
    • Membrane: Nylon 6,6
    • Support Media: Polypropylene
    • End Caps: Polypropylene
    • Center Core: Polypropylene
    • Outer Support Cage: Polypropylene
    • O-Rings/Gaskets: Buna, EPDM, Silicone, Teflon® Encapsulated Viton®, Viton®, Teflon® Encapsulated Silicone

Operating limits

  • Operating Conditions
    • Change Out ΔP (recommended): 35 PSID
    • Temperature (max): 176˚F (80˚C)
    • Differential Pressure (max): 50 PSID (3.4 bar) at 68˚F (20˚C)
  • Sanitization/Sterilization
    • Filtered Hot Water: 80˚C for 30 min.
    • Steam Sterilization: 121˚C for 30 min., multiple cycles
    • Chemicals: Cartridges are compatible with most chemical sanitizing agents.
    • Note: Stainless steel insert option required for all cartridges being hot water sanitized or steam sterilized.

Product water

Microbial Retention Performance (Independently tested in accordance with ASTM F838)

  • Grade 0.2 µ
    • Challenge Microbe: Brevundimonas diminuta
    • Log Reduction Value (LRV): 9.1
  • Grade 0.45 µ
    • Challenge Microbe: Serratia marcescens
    • Log Reduction Value (LRV): 11.0
  • Grade 0.65 µ
    • Challenge Microbe: Saccharomyces cerevisiae
    • Log Reduction Value (LRV): 11.0

Compliance / Safety

  • Toxicity
    • All polypropylene components meet the specifications for biological safety per USP Class VI – 121˚C for plastics.
  • Food Safety Compliance
    • Materials of construction comply with FDA regulations for food and beverage contact use as detailed in the US Code of Federal Regulations, 21CFR.
    • Materials used to produce filter media and hardware are deemed safe for use in contact with foodstuffs in accordance with EU Directives 2002/72/EC, 1935/2004, and/or 10/2011.

Flow Rate vs Pressure Drop

See the official PDF for exact tabulated values.

Ordering Information

The following options are available for GFHNY and GFHNY+:

  • Rating (µ)
    • 0.03
    • 0.05
    • 0.1
    • 0.2
    • 0.45
    • 0.65
    • 0.8
    • 1.2
  • Length
    • 10” (25.4 cm)
    • 20” (50.8 cm)
    • 30” (76.2 cm)
    • 40” (101.6 cm)
  • End Cap Style
    • 2 = DOE Flat Gasket
    • 3 = 222 w/ Fin
    • 4 = 222 w/ Flat Cap
    • 6 = 226 w/ Flat Cap
    • 7 = 226 w/ Fin
    • 16 = 213 Internal O-Ring
    • 28 = 222 3-tabs w/ Fin
  • O-Rings/Gaskets
    • B = Buna
    • E = EPDM
    • S = Silicone
    • T = Teflon® Encapsulated Viton®
    • V = Viton®
    • Z = Teflon® Encapsulated Silicone
  • Adders
    • CS = 316SS Compression Spring
    • I = Stainless Steel Insert

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.