Datasheet summary
Harmsco Hurricane housings
Engineering summary from PDF text extraction for Harmsco Hurricane housings. Verify every value with the OEM datasheet.
Summary
Product Identification
The HARMSCO® HP Hurricane® Filter Housings are designed for unsurpassed performance by separating dense solids prior to cartridge filtration, leading to extended filter life, increased dirt holding capacity, and reduced maintenance costs. They feature a combination cyclone separator and cartridge filter in a single compact design.
Available models include:
- HUR 40 HP
- HUR 90 HP
- HUR 170 HP
Key features:
- Patented Up-flow design with tangential entry to prevent air entrapment.
- Rotational flow that "flutters" media pleats, improving loading performance.
- CPVC standpipe as standard (stainless steel optional).
- Three sizes available to provide greater media surface area.
- NSF 61 listed.
- Extensive choice of cartridge micron ratings and media, including carbon block.
- Electropolished 304 stainless steel housing (316 available upon request).
- Fail-Safe closure system.
Applications
HP Hurricane® Filter Housings are suitable for a wide range of applications:
- Commercial/Residential Drinking Water
- Industrial Waste Water Treatment
- Surface Water Treatment Rule (SWTR) I, II
- Process Water
- Cooling Tower Filtration
- Whole House Filtration
- Reverse Osmosis Pre-filtration
- Desalination Pre-filtration (with 316 and coated options)
- Ground Water Remediation
- Ground Water Under Direct Influence (GUDI)
- Well Water
- Small Community Compliance (cysts)
Operating Limits
- Max Pressure: 150 psi (10 bar)
- Max Temperature: 140˚F (60˚C)
- Up to 250˚F (121˚C) with optional stainless steel standpipe and high temperature cartridges installed.
- Harmsco® recommends operation at 70% of maximum flow rate for optimum performance.
Mechanical / Hydraulic
Housing Materials:
- Housing: Electropolished 304 stainless steel (316 available upon request).
- Standpipe: CPVC (standard); stainless steel optional for high temperature.
- Rim gaskets: EPDM (Buna-N, Viton available).
- Wing nuts: Brass.
Connections:
- Gauge sample ports: 1/4” (inlet and outlet)
- Pipe Size NPT: 2”
- Drain Size NPT: 1”
- BSTP optional
- Features a 90˚ elbow and 45˚ sweep on outlet for staggered in-line vertical installation.
Housing Dimensions:
| Filter Model | Filter Height | Width | Diameter | Inlet | Outlet | Floor Space | Service Ht. | Shipping Wt. |
|---|---|---|---|---|---|---|---|---|
| HUR 40 HP | 19-1/2” | 14-5/8” | 13” | 12-3/4” | 3-7/16” | 15x15 In. | 35” | 40 Lbs |
| HUR 90 HP | 29-7/8” | 14-5/8” | 13” | 17-3/4” | 3-7/16” | 15x15 In. | 51” | 52 Lbs |
| HUR 170 HP | 40-1/2” | 14-5/8” | 13” | 23-5/8” | 3-7/16” | 15x15 In. | 72” | 64 Lbs |
Cartridges
Hurricane® cartridges are cleanable and reusable in most applications and micron ratings (5 micron and up).
Cartridge Dimensions:
| Filter Model | Length | O.D. |
|---|---|---|
| HUR 40 HP | 9-5/8” | 7-3/4” |
| HUR 90 HP | 19-1/2” | 7-3/4” |
| HUR 170 HP | 30-3/4” | 7-3/4” |
Cartridge Media Options & Micron Ratings:
- Polyester (NSF 61 Listed): Engineered for high efficiency, low pressure drops. Available in 0.35, 1, 5, 10, 20, 50, 100, 150 Micron ratings across HUR 40, HUR 90, and HUR 170 models.
- Flow Rates (Polyester):
- HUR 40 HP: Up to 50 GPM max, 35 GPM recommended. Up to 189 LPM, Up to 12 M³/HR.
- HUR 90 HP: Up to 100 GPM max, 70 GPM recommended. Up to 378 LPM, Up to 24 M³/HR.
- HUR 170 HP: Up to 150 GPM max, 105 GPM recommended. Up to 568 LPM, Up to 36 M³/HR.
- Media Area: HUR 40 HP (40 sq.ft.), HUR 90 HP (90 sq.ft.), HUR 170 HP (170 sq.ft.).
- Flow Rates (Polyester):
- High Temperature: For applications up to 200°F (93°C), or up to 250°F (121°C) with metal end caps. Specific micron ratings are available.
- Harmsco Free (NSF 61 Listed): 100% synthetic composite media. Available in 1, 5, 20 Micron ratings.
- Poly-Pleat (NSF 61 Listed): 1 micron absolute, multi-layered media. Available in 1 Micron rating. "Fail Safe" versions also available.
- Recommended Flow Rates (Poly-Pleat): HUR 40 HP (15 GPM), HUR 90 HP (25 GPM), HUR 170 HP (50 GPM).
- Media Area: HUR 40 HP (25 sq.ft.), HUR 90 HP (50 sq.ft.), HUR 170 HP (100 sq.ft.).
- All-Poly (NSF 61 Listed): 100% polypropylene media with polypropylene end caps and components. Available in 0.2, 0.45, 1, 5 Micron ratings; also available in 10, 20, and 50 micron ratings.
- Flow Rates (All-Poly):
- HUR 40 HP: 25 GPM max, 17 GPM recommended.
- HUR 90 HP: 50 GPM max, 35 GPM recommended.
- HUR 170 HP: 100 GPM max, 60 GPM recommended.
- Media Area: HUR 40 HP (25 sq.ft.), HUR 90 HP (50 sq.ft.), HUR 170 HP (75 sq.ft.).
- Flow Rates (All-Poly):
- SureSafe Antimicrobial: Reduces growth of bacteria and mold on media. Available in 20, 50 Micron ratings.
- Carbon Block (NSF 42 Listed): Includes pleated 5 micron nominal pre-filtration.
- Recommended Flow Rates (Carbon Block for maximum chlorine removal): HUR 40 HP (5 GPM), HUR 90 HP (10 GPM), HUR 170 HP (15 GPM).
- Media Area: HUR 40 HP (25 sq.ft.), HUR 90 HP (55 sq.ft.), HUR 170 HP (90 sq.ft.).
- EZ Clean: 100% synthetic composite 50 micron media. Available in 50 Micron rating.
- Poly-Mesh: 100% synthetic composite 250 micron media. Available in 250 Micron rating for HUR 170.
Cartridge Characteristics: A variety of cartridges offer features for Sediment Removal, Turbidity Reduction, Chlorine Removal, Taste & Odor Reduction, Cyst Removal, Absolute Rating, Nominal Rating, 100% Synthetic media, Course Filtration, High Temperature capability, All Polypropylene construction, Cleanable/Reusable properties, NSF Listing (61 or 42), Non-Potable Use, Pre-Filtration, Post-Filtration, and Antimicrobial properties. See the official PDF for exact tabulated values for each cartridge type.
Pressure Drop
Pressure drop data, developed by NSF International, indicates total head loss for Hurricane® filter housings with 20 micron filter cartridges in clean water. Refer to the official PDF for graphical representations of flow rate vs. total head loss.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data and complete product information, the official PDF revision used on the project must be consulted.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.