Back to Harmsco Filtration
Harmsco logo

Datasheet summary

Harmsco Hurricane Installation & Operation Manual

Engineering summary from PDF text extraction for Harmsco Hurricane Installation & Operation Manual. Verify every value with the OEM datasheet.

Summary

Product Identification

The HARMSCO® Hurricane® Filters are designed for long filter runs, reduced maintenance, and lower filtration costs. They function as a combination centrifugal separator and cartridge filter or in conventional filtration applications. The system utilizes up-flow cartridge filtration, and replacement cartridges can be cleaned and reused in most applications and micron ratings.

Models available:

  • HUR 40 HP
  • HUR 90 HP
  • HUR 170 HP

Features

  • 304 stainless steel filter housings
  • Electro-polished for superior finish
  • Resistant coatings available
  • Fail-safe lids with individual studs for security
  • Brass wing-nuts for convenience
  • 90˚ elbow and 45˚ sweep on outlet for in-line vertical installation
  • CPVC standpipe for up-flow design
  • Choice of cartridges available

Operating Limits

  • Pressure Rating: Up to 150 psi
  • Temperature Rating: Up to 140°F (60°C). Note: This varies based on pressure and time under load.
  • pH Range (for cartridges): 3 to 11

Mechanical / Hydraulic

Filter Models & Specifications:

SPECIFICATIONHUR 40 HPHUR 90 HPHUR 170 HP
Flow rate (GPM)Up to 50Up to 100Up to 150
Filter area (pleated)40 sq. ft.90 sq. ft.170 sq. ft.
Pipe sizes, inlet & outlet2” NPT2” NPT2” NPT
Pipe size, drain1” NPT1” NPT1” NPT
Filter height21”31”41”
Filter diameter13”13”13”
Floor space required15”x15”15”x15”15”x15”
Service height clearance31”51”72”
Shipping weight (approx.)40 lbs.51 lbs.64 lbs.

Housing Dimensions:

ModelA HeightB WidthC DiameterD InletE Outlet
HUR 40 HP19 1/2”14 5/8”13”12 3/4”3 7/16”
HUR 90 HP29 7/8”14 5/8”13”17 3/4”3 7/16”
HUR 170 HP40 1/2”14 5/8”13”23 5/8”3 7/16”

Note: Dimensions A, B, C, D, E refer to specific points on a diagram in the official PDF.

Components:

  • Rim gasket: EPDM (standard), Buna-N (optional), Viton (optional)
  • Retainer nut: PVC
  • Top plate: Stainless steel
  • Retainer nut insert: PVC
  • Lid: Stainless steel with vent
  • Standpipe: CPVC (specific models: 316-C for HUR 40 HP, 317-C for HUR 90 HP, 315-C for HUR 170 HP)
  • Wing-nut: Brass
  • Inner vessel isolator: CPVC
  • Screw (for isolator): Stainless steel, 1/4” x 1/2”

Cartridge Specifications & Sizing

Hurricane® filter cartridges are made of Polyester Plus™, a proprietary blend of polyester fibers. They are available in a wide range of micron ratings and can be cleaned and reused. Activated carbon and Poly-Pleat Hurricane® cartridges are also available.

Recommended Sizing by Flow Rate:

Flow RateRecommended ModelPleated Filter Area
Up to 50 GPMHUR 40 HP40 sq. ft.
Up to 100 GPMHUR 90 HP90 sq. ft.
Up to 150 GPMHUR 170 HP170 sq. ft.
Up to 300 GPMHUR 170 HP (two filters*)340 sq. ft. (two filters*)
Up to 450 GPMHUR 170 HP (three filters*)510 sq. ft. (three filters*)
Up to 600 GPMHUR 170 HP (four filters*)680 sq. ft. (four filters*)
Up to 750 GPMHUR 170 HP (five filters*)850 sq. ft. (five filters*)
*Parallel installation with valves to isolate filters for service while other filters are operational.

Replacement Cartridge Specifications:

Filter ModelCartridge Product CodeNominal MicronCartridge Dimensions (Length)Cartridge Dimensions (Diameter)Cartridge Dimensions (Connection)Ship Wt./Ctn. (One Cartridge)
HUR 40 HPHC/40-0.350.359 5/8”7 3/4”3” FPT4 lbs.
HC/40-119 5/8”7 3/4”3” FPT4 lbs.
HC/40-559 5/8”7 3/4”3” FPT4 lbs.
HC/40-10109 5/8”7 3/4”3” FPT4 lbs.
HC/40-20209 5/8”7 3/4”3” FPT4 lbs.
HC/40-50509 5/8”7 3/4”3” FPT4 lbs.
HC/40-1001009 5/8”7 3/4”3” FPT4 lbs.
HC/40-1501509 5/8”7 3/4”3” FPT4 lbs.
HC/40-EZ-CLEANNR*9 5/8”7 3/4”3” FPT4 lbs.
HUR 90 HPHC/90-0.350.3519 1/2”7 3/4”3” FPT7 lbs.
HC/90-1119 1/2”7 3/4”3” FPT7 lbs.
HC/90-5519 1/2”7 3/4”3” FPT7 lbs.
HC/90-101019 1/2”7 3/4”3” FPT7 lbs.
HC/90-202019 1/2”7 3/4”3” FPT7 lbs.
HC/90-505019 1/2”7 3/4”3” FPT7 lbs.
HC/90-10010019 1/2”7 3/4”3” FPT7 lbs.
HC/90-15015019 1/2”7 3/4”3” FPT7 lbs.
HC/90-EZ-CLEANNR*19 1/2”7 3/4”3” FPT7 lbs.
HUR 170 HPHC/170-0.350.3530 3/4”7 3/4”3” FPT10 lbs.
HC/170-1130 3/4”7 3/4”3” FPT10 lbs.
HC/170-5530 3/4”7 3/4”3” FPT10 lbs.
HC/170-101030 3/4”7 3/4”3” FPT10 lbs.
HC/170-202030 3/4”7 3/4”3” FPT10 lbs.
HC/170-505030 3/4”7 3/4”3” FPT10 lbs.
HC/170-10010030 3/4”7 3/4”3” FPT10 lbs.
HC/170-15015030 3/4”7 3/4”3” FPT10 lbs.
HC/170-EZ-CLEANNR*30 3/4”30 3/4”3” FPT10 lbs.
*NR - not rated.

Cartridge Cleaning Guidelines:

  • Clean cartridges when pressure differential is 12 psi above startup differential.
  • Replace non-cleanable cartridges when pressure differential is 30 psi above start-up differential or when flow diminishes to an unacceptable level.
  • Cleaning is generally not possible for petroleum-base liquids, toxic substances, and one micron and below applications.
  • For oils: Soak in a solution of tri-sodium phosphate or similar strong detergent (2 lbs. to 10 gallons of water) for up to 12 hours.
  • For organic matter, algae: Use tri-sodium phosphate solution plus 1 pint of liquid chlorine; soak one hour or longer.
  • For calcium mineral deposits: Soak for approximately ten minutes in a solution of one part muriatic acid to twenty parts of water. Caution: Do not rinse cartridges with acid until oils and organic matter are removed.

Pressure Drop

The official PDF includes total head loss data developed by NSF International, showing pressure drop with Hurricane® Filters and one micron filter cartridges in clean water. These are presented as graphs plotting Total Head Loss (P.S.I.) against Flow Rate (GPM) for HUR 40 HP, HUR 90 HP, and HUR 170 HP models. See the official PDF for exact tabulated values and graphical representation.

Centrifugal Separation

Liquid enters the filter's outer chamber tangentially, creating a rotational flow and centrifugal force. This force separates dense particles (e.g., sand, rust, grit, metal fines), which drop to the bottom and can be discharged manually, automatically, or continuously. Lighter solids and liquid then rise into an inner chamber for further filtration.

Disclaimer

This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the original OEM PDF datasheet. For contractual data and complete information, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)