Datasheet summary
Harmsco Hurricane Polyester Filter Cartridges
Engineering summary from PDF text extraction for Harmsco Hurricane Polyester Filter Cartridges. Verify every value with the OEM datasheet.
Summary
Product identification
Harmsco® Premium Hurricane® Polyester Cartridges are designed for Hurricane® and WaterBetter® Filter Housings. Made in USA, these cartridges offer high flow capability and lower overall operating costs.
Key features include:
- High flow performance
- Lower overall operating cost
- Reduced waste disposal
- Longer filter runs for fewer change-outs
- Increased contaminant removal
- Operator friendly
- Fewer cartridges for fewer change-outs and lower maintenance cost
- Pleated Polyester-Plus™ filter media for higher flow rates and lower initial pressure drop
- Pleated surface area for higher loading capacity, longer filter life, and increased particle removal
- End cap, center tube, and media are thermally bonded as one integral component for added strength
- Offered in three sizes (40, 90, and 170) and eight micron ratings (0.35, 1, 5, 10, 20, 50, 100, and 150)
- Cleanable/Reusable in most filtration applications and micron ratings
Operating limits
- Temperature: 140˚F (60˚C) temperature limit. Temperature limits may vary depending on pressure and time under load.
- Recommended Operation: Harmsco® recommends operation at 70% of maximum flow rate for optimum performance.
Mechanical / hydraulic
Specifications
- Micron Ratings: Nominal micron ratings of 0.35, 1, 5, 10, 20, 50, 100, 150
- End Caps: Pliable PVC with built-in sealing surface
- Filter Media: Nominal pleated Polyester-Plus™
- Center Tubes: ABS or PVC
- Outside Diameter (O.D.): 7-3/4”
- Cartridge Lengths:
- Size 40: 9-5/8”
- Size 90: 19-1/2”
- Size 170: 30-3/4”
Cartridge Selection/Sizing Guide - Premium Hurricane® Polyester Cartridges (rated up to 140˚F / 60˚C)
| Product Code | Nominal Micron Rating | Media (sq ft) | Recommended Flow Rate* (GPM) | Max Flow Rate* (GPM) | Max Flow Rate* (LPM) | Max Flow Rate* (M³/HR) | No./Carton | Carton Size |
|---|---|---|---|---|---|---|---|---|
| HC/40-0.35 | 0.35 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-1 | 1 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-5 | 5 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-10 | 10 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-20 | 20 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-50 | 50 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-100 | 100 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/40-150 | 150 | 40 | 35 | 50 | 189 | 12 | 1 | 9x9x11 |
| HC/90-0.35 | 0.35 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-1 | 1 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-5 | 5 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-10 | 10 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-20 | 20 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-50 | 50 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-100 | 100 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/90-150 | 150 | 90 | 70 | 100 | 378 | 24 | 1 | 9x9x21 |
| HC/170-0.35 | 0.35 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-1 | 1 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-5 | 5 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-10 | 10 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-20 | 20 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-50 | 50 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-100 | 100 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
| HC/170-150 | 150 | 170 | 105 | 150 | 568 | 36 | 1 | 9x9x32 |
A pressure drop chart shows Total Head Loss (psi) versus Flow Rate (GPM) for different cartridge sizes (HUR 40 HP, HUR 90 HP, HUR 170 HP) using a 20 micron filter cartridge in clean water. See the official PDF for exact tabulated values.
Applications
- Cooling Tower Filtration
- Chill Water Loop Filtration
- Food & Beverage Filtration
- Marine/Aquatic Filtration
- Industrial Coolant Filtration
- Commercial/Residential Drinking Water Filtration
- Municipal Drinking Water Filtration
- Reverse Osmosis Pre-filtration
- Desalination Pre-filtration
- Industrial Water Filtration
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.