Summary

Product identification

  • Model: Auto-line© VLR–E
  • Material: Stainless acid-proof EN 1.4404 steel
  • Compliance:
    • Pressure equipment directive 2014/68/EC article 4, section 3
    • Complies with EMC directive
    • CE labelled
    • Test pressure according to EN 13445
  • Features: Ready for installation, complete with electronic controller and automatic drain-valve.
  • Installation Note: Must be installed as a pressure filter in systems with positive overpressure.

Operating limits

  • Design pressure: 10 bar
  • Test pressure: According to EN 13445
  • Max differential pressure: 3.0 bar
  • Max working temperature: 80°C (Fluid grp. 2 and steam pre. < 0.5 bar)

Electrical

  • Power supply: 3 x 230/400V, 50 Hz

Mechanical / hydraulic

  • Volume: 485 litres
  • Weight: 650 kg
  • Flange connection: DN300 PN16 EN1092-1/11
  • Drain: Rp2 or flange DN50 PN16 EN1092-1/11
  • Sludge chamber volume: 22 litres
  • Filtration: 100-150-200-300-500-1000 micron
  • Strainer area: 14.400 cm²

Capacity

Capacity is provided in m³/h at a viscosity of 1 cSt for various micron ratings (100, 150, 300, 500, 1000) and differential pressures (0.05, 0.10, 0.15, 0.20 bar). See the official PDF for exact tabulated values.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. Contractual data must match the OEM PDF revision used on the project.