Datasheet summary
PSS Filter Elements
Engineering summary from PDF text extraction for PSS Filter Elements. Verify every value with the OEM datasheet.
Summary
Product identification
PSS® Series filter elements are composed of 316 low-carbon stainless steel powder sintered together in an inert environment. The medium provides a fixed pore structure, quantitative particle removal efficiency without media migration or particle unloading, inherently high void volume, low resistance to flow, and high dirt holding capacity. These filters are repeatedly cleanable and offer broad temperature and chemical compatibility.
They exhibit high chemical stability and do not impart taste, odor, or extractables to the effluent.
Applications
- Chemical process industry
- Aggressive environments requiring critical filtration levels
- Industrial gases (cryogenic and high temperature)
- Steam
- Solvent
- Heat transfer fluids
- Polymers
- Chemical intermediates
- Food and beverages
Operating limits
- Collapse differential pressure (Standard 316 stainless steel cartridges):
- 50 psid in the forward flow (outside-in) direction up to 600°F (✝)
- 50 psid in the reverse flow direction
- ✝Threaded connector series only. 1000 Series suitable for applications up to 450°F due to seal limitations.
- Temperature: Designs available for temperatures up to 1250°F with appropriate alloy selection.
Physical characteristics
PSS filters are available in three styles:
- Industrial (1000 style): 2 3⁄8-inch diameter double open-ended modules in incremental lengths of 10 inches.
- Sanitary design (AB style): Closed on one end with an O-ring piston seal on the other end.
- Cylindrical elements: 1 1⁄2-inches or 2 3⁄8-inches in diameter, closed on one end with a threaded fitting connection on the other.
Performance data
Filter Element Characteristics
- Filter Grade PO5
- Removal Ratings:
- Liquid Service: 0.5 µm (50%), 2 µm (90%), 3 µm (99%), 5 µm (100%)
- Gaseous Service (weight % removal based on AC Fine Test Dust in air): 99.99%
- Clean Pressure Drop:
- Liquid Service (psi/gpm/ft²): 0.4
- Gaseous Service (psi/acfm/ft²): 0.85
- Recommended Flow Density:
- Aqueous (gpm/ft²): 0.091
- Air (acfm/ft²): 0.5 - 2
- Removal Ratings:
- Filter Grade PO9
- Removal Ratings:
- Liquid Service: 2 µm (50%), 4 µm (90%), 7 µm (99%), 9 µm (100%)
- Gaseous Service (weight % removal based on AC Fine Test Dust in air): 99.98%
- Clean Pressure Drop:
- Liquid Service (psi/gpm/ft²): 0.8
- Gaseous Service (psi/acfm/ft²): 0.27
- Recommended Flow Density:
- Aqueous (gpm/ft²): 0.030
- Air (acfm/ft²): 0.75 - 3
- Removal Ratings:
- Filter Grade H
- Removal Ratings:
- Liquid Service: 5 µm (50%), 7 µm (90%), 9 µm (99%), 13 µm (100%)
- Gaseous Service (weight % removal based on AC Fine Test Dust in air): 99.97%
- Clean Pressure Drop:
- Liquid Service (psi/gpm/ft²): 1.3
- Gaseous Service (psi/acfm/ft²): 0.23
- Recommended Flow Density:
- Aqueous (gpm/ft²): 0.024
- Air (acfm/ft²): 1 - 4
- Removal Ratings:
- Filter Grade F
- Removal Ratings:
- Liquid Service: 8 µm (50%), 12 µm (90%), 15 µm (99%), 20 µm (100%)
- Gaseous Service (weight % removal based on AC Fine Test Dust in air): 99.94%
- Clean Pressure Drop:
- Liquid Service (psi/gpm/ft²): 2.8
- Gaseous Service (psi/acfm/ft²): 0.052
- Recommended Flow Density:
- Aqueous (gpm/ft²): 0.0054
- Air (acfm/ft²): 2 - 6
- Removal Ratings:
- Filter Grade E
- Removal Ratings:
- Liquid Service: 15 µm (50%), 22 µm (90%), 25 µm (99%), 35 µm (100%)
- Gaseous Service (weight % removal based on AC Fine Test Dust in air): 99.80%
- Clean Pressure Drop:
- Liquid Service (psi/gpm/ft²): 11.0
- Gaseous Service (psi/acfm/ft²): 0.019
- Recommended Flow Density:
- Aqueous (gpm/ft²): 0.0013
- Air (acfm/ft²): 2 - 7
- Removal Ratings:
- Filter Grade D
- Removal Ratings:
- Liquid Service: 20 µm (50%), 28 µm (90%), 40 µm (99%), 55 µm (100%)
- Gaseous Service (weight % removal based on AC Fine Test Dust in air): 99.50%
- Clean Pressure Drop:
- Liquid Service (psi/gpm/ft²): 20.0
- Gaseous Service (psi/acfm/ft²): 0.0068
- Recommended Flow Density:
- Aqueous (gpm/ft²): 0.0007
- Air (acfm/ft²): 3 - 10
- Removal Ratings:
Notes on performance data
- Removal ratings with * (e.g., 50%) should be used when comparing PSS to competitive grades.
- (1) Liquid removal efficiency ratings are based on a modified F2 test method and actual particle count data.
- (2) Weight percent removal data based on AC Fine Test Dust in air. Absolute retention ratings based on actual particle count.
- (3) Pressure drop in psi obtained by multiplying value shown by actual flow desired in gpm, viscosity of liquid in centipoise (if other than 1 cp), all divided by total filtration area (ft²).
- (4) Pressure drop in psi obtained by multiplying value shown by actual gaseous flow rate desired (acfm), ratio of viscosities (Actual viscosity of gas in cp / 0.018 (viscosity of air)), all divided by total filtration area (ft²).
Part numbers / Ordering information
Gasket Options (Code ▲)
- H13: Nitrile (Std.)
- H: Fluorocarbon Elastomer
- J: Ethylene Propylene
- J7: Ethylene Propylene for Steam Service
Nominal Length and Area Codes
- For 100 Series (MBS100) (Code ■)
- 1: Length 10 in, Area 0.5 ft²
- 2: Length 20 in, Area 1.0 ft²
- 3: Length 30 in, Area 1.5 ft²
- For Cylindrical 2 3⁄8" Diameter Elements (C-23-) (Code ●)
- 06: Length 6 in, Area 0.31 ft²
- 09: Length 9 in, Area 0.47 ft²
- 18: Length 18 in, Area 0.9 ft²
- 19: Length 19 in, Area 0.98 ft²
- For Cylindrical 1 1⁄2" Diameter Elements (C-14-) (Code ★)
- 06: Length 6 in, Area 0.2 ft²
- 09: Length 9 in, Area 0.29 ft²
- 18: Length 18 in, Area 0.59 ft²
Connection Options (Code ◆)
- 1: 1⁄4" NPT
- 4: 1" NPT
- 6: 1 1⁄2" NPT
PSS Series Element Part Number Structure
- 100 Series (2 3⁄8" Diameter Elements):
- MBS100■[100% Removal Rating Code]▲
- PO5: MBS100■PO5▲
- PO9: MBS100■PO9▲
- PH: MBS100■PH▲ (for 13 µm)
- PF: MBS100■PF▲ (for 20 µm)
- PE: MBS100■PE▲ (for 35 µm)
- PD: MBS100■PD▲ (for 55 µm)
- MBS100■[100% Removal Rating Code]▲
- AB Series (Sanitary Design):
- AB■[100% Removal Rating Code]7▲
- PO5: AB■PO57▲
- PO9: AB■PO97▲
- PH: AB■PH7▲ (for 13 µm)
- PF: AB■PF7▲ (for 20 µm)
- PE: AB■PE7▲ (for 35 µm)
- PD: AB■PD7▲ (for 55 µm)
- AB■[100% Removal Rating Code]7▲
- Cylindrical 2 3⁄8" Diameter Elements (with 1" or 1 1⁄2" NPT):
- C-23-●◆[100% Removal Rating Code]
- PO5: C-23-●◆PO5
- PO9: C-23-●◆PO9
- PH: C-23-●◆PH (for 13 µm)
- PF: C-23-●◆PF (for 20 µm)
- PE: C-23-●◆PE (for 35 µm)
- PD: C-23-●◆PD (for 55 µm)
- C-23-●◆[100% Removal Rating Code]
- Cylindrical 1 1⁄2" Diameter Elements (with 1⁄4" NPT):
- C-14-★◆[100% Removal Rating Code]
- PO5: C-14-★◆PO5
- PO9: C-14-★◆PO9
- PH: C-14-★◆PH (for 13 µm)
- PF: C-14-★◆PF (for 20 µm)
- PE: C-14-★◆PE (for 35 µm)
- PD: C-14-★◆PD (for 55 µm)
- C-14-★◆[100% Removal Rating Code]
Connection Code Details
- (5) C-23-19 has connection Code 6 (1 1⁄2" NPT). Other C-23 part numbers have Code 4 (1" NPT). All C-14 part numbers have Code 1 (1⁄4" NPT).
Housing information
A full selection of standard Pall industrial housings are available for use with PSS elements. Custom designed housings for specific applications are also available.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.