Back to Pall filters
Pall logo

Datasheet summary

Emflon Filters

Engineering summary from PDF text extraction for Emflon Filters. Verify every value with the OEM datasheet.

Summary

Product identification

The Emflon® filter is recommended for chemicals compatible with PTFE and polypropylene. Key features include:

  • Wide range of configurations
  • Five removal ratings
  • High flow rates
  • Integrity testable
  • Low extractables
  • Optimized design
  • Manufactured in a cleanroom environment
  • 100% integrity tested

Materials

  • Medium: PTFE
  • Core, cage, and end caps: Polypropylene
  • Support and drainage: Polypropylene
  • O-ring options: Viton¹ and Teflon encapsulated Viton

Mechanical / hydraulic

  • Removal Ratings: 5.0 µm, 1.0 µm, 0.2 µm, 0.1 µm, 0.05 µm
  • Filter Areas:
    • 10" / 254 mm: 9.45 ft² / 0.88 m²
    • 20" / 508 mm: 18.90 ft² / 1.76 m²
    • 30" / 762 mm: 28.35 ft² / 2.64 m²
    • 40" / 1016 mm: 37.80 ft² / 3.52 m²
  • Configurations:
    • Nominal length: 10" / 254 mm, 20" / 508 mm, 30" / 762 mm, and 40" / 1016 mm
    • Diameter: 2.75" / 70 mm
    • O-ring size / end caps:
      • Code 3 (222 double O-ring / flat end)
      • Code 8 (222 double O-ring / finned end)
      • Code 7 (226 double O-ring bayonet lock / finned end)
  • Operating Conditions:
    • Maximum Operating Temperature: 194°F / 90°C
    • Maximum Forward Differential Pressure:
      • 80 psid @ 120°F / 5.5 bar @ 50°C
      • 50 psid @ 121° - 195°F / 3.5 bar @ 51°- 90°C
  • Integrity Test Values² (Per 10" / 254 mm segment):
    • 0.05 µm: < 45 mL / min @ 35 psig / 2.4 bar
    • 0.1 µm: < 64 mL / min @ 19 psig / 1.3 bar
    • 0.2 µm: < 32 mL / min @ 11 psig / 0.76 bar
  • Pressure Drop vs. Liquid Flow Rate: The document includes a graph illustrating clean pressure drop versus liquid flow rate for 10" / 254 mm cartridges, specifying different µm ratings. For liquids with viscosity differing from water, multiply the pressure drop by the viscosity in centipoise. See the official PDF for exact tabulated values.

Ordering Information: Part numbers are available for various removal ratings, nominal lengths, configuration codes, and O-ring materials (including Ethylene Propylene, Viton A, and Teflon Encapsulated Viton). Options exist for prewet configurations. Other O-ring materials are available. See the official PDF for exact part number configurations.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.