HDC II Filter Cartridges

Engineering summary from PDF text extraction for HDC II Filter Cartridges. Verify every value with the OEM datasheet.

Summary

Product Identification

HDC® II filter cartridges are constructed from pure polypropylene, featuring high-area pleated media. This new generation of HDC II filters incorporates a proprietary design that varies the fiber diameter continuously from coarse (upstream) to fine (downstream), significantly increasing dirt-holding capacity. This design allows for up to four times longer service life compared to other filters of similar appearance.

Removal ratings range from 0.6 µm (micron) to 70.0 µm absolute. All materials of construction are FDA-listed for direct food contact, and all components have been tested according to USP Class VI biological tests for plastics at 250˚F (121°C).

Operating Limits

  • HDC "J" Series filters: Recommended maximum pressure differential is 75 psid up to 140°F (60°C).
  • UNI CAP filters (HDC "J" Series configuration): Recommended maximum pressure differential is 45 psid up to 180°F (82°C).
  • AB style filters: Recommended maximum pressure differential is 80 psid up to 122°F (50°C) and 60 psid up to 176°F (80°C).
  • Warning: Using these filters for filtration at higher pressures or temperatures than recommended, or with fluids incompatible with polypropylene, can result in property damage, personal injury, and contaminated filtrate.

Mechanical / Hydraulic

  • HDC II “J” Series (UNI CAP configuration):
    • Outer Diameter: 2 1/2"
    • Lengths: 10, 20, 30, and 40 inches.
    • Sealing: Elastomeric gaskets attached to each end cap.
  • Sanitary (AB Style) elements:
    • Outer Diameter: 2 3/4"
    • Lengths: 10, 20, 30, and 40 inches.
    • Configuration: Single open-ended with an O-ring piston seal at the open end.
  • Housings: Available in polypropylene, other polymers, and carbon steel.

Cartridge Lengths (available for "J" Series):

  • 10”
  • 20”
  • 30”
  • 40”

Performance Data for 10" Modules: See the official PDF for exact tabulated values for liquid removal rating, aqueous clean pressure drop, and typical flow rate for each grade (J006 to J700). The table includes removal ratings at 90% and 99.98% efficiency, pressure drop in PSI per GPM water, and typical flow rate in GPM.

Ordering Information / Part Numbers

  • Grade (99.98% Removal Rating µm):
    • J006: <1.0*
    • J012: 1.2
    • J025: 2.5
    • J045: 4.5
    • J060: 6.0
    • J100: 10
    • J200: 20
    • J400: 40
    • J700: 70
  • Application Option:
    • Omit: Other
    • P: Pharmaceutical
  • O-Ring Option:
    • H4: Silicone (Standard)
    • H: Viton A*
    • J: Ethylene Propylene
  • Gasket Option:
    • H13: Buna N
    • H: Viton A
    • J: Ethylene Propylene (Std)
  • End Fittings (AB Style):
    • 3: O-Ring Fitting I.D. 1 1/4 In. (-222, Flat end)
    • 7: O-Ring Fitting I.D. 1 1/2 In. (-226, Finned end & bayonet lock)
    • 8: O-Ring Fitting I.D. 1 1/4 In. (-222, Finned end)

Applications

HDC II filters are designed for applications where economy and reliability are critical, including:

  • General Service: Rinse water, reverse osmosis system pre-filtration, water–prior to and/or after demineralization.
  • General Process Industries: Electroplating solutions, metal etching solutions, audio and video tape coatings, automotive paints, can coatings, coil coatings, computer tape and disc coatings, photographic film manufacturing and processing.
  • Chemical/Petrochemical Industries: Amines for gas scrubbing, monomers, polymers, glycols, herbicides and pesticides, liquid catalysts, product polishing, photoresists, acids, bases, solvents, deep well disposal fluids.
  • Film and Fiber Industries: Monomers, quench water, slurry additives, delusterants, slip agents, D.I. water, solvents, spin finishes, aqueous salt solutions.
  • Power Generation Industries: Makeup water, laundry drain wastewater, steam generator blowdown prefilters.
  • Pharmaceutical Industry: Parenterals, ophthalmics, oral medications.
  • Biological Industry: Serum and serum fractions, tissue culture media, vaccine preparations, microbiological growth media, media makeup water, diagnostic sera.
  • Cosmetics: Toiletries, aftershaves, perfumes, oils, lotions, creams, ointments, shampoos, body rinses, mouthwashes.
  • Fermentation Industries: Liquid growth media, makeup water, intermediates, final liquid products, additives, exhaust gas, prefiltration.
  • Food and Beverage Industries: Potable liquids, wine, beer, soft drinks, flavors, storage tank/reactor vents, corn syrup, edible oils.
  • Electronic Industries: Photoresists, acids, bases, solvents, etchant gases, D.I. water prefiltration.